Slush Freezer
Troubleshooting Chart
TURN WATER
SUPPLY ON IF
OFF
REPOSITION
WATER LINES
IF KINKED
CHECK TO
SEE IF TOP
TORQUE
SPRING IS
ATTACHED
OPERATOR COMPLAINT IS:
“PRODUCT WILL NOT FREEZE”
IF PROBLEM PERSISTS
CONTACT H. C. DUKE & SON, INC. / ELECTRO FREEZE
SERVICE DEPARTMENT AT
800/755-4545
IF AIR
COOLED
CHECK FOR
AIR INTAKE/
DISCHARGE
BLOCKAGE
IF WATER
COOLED
CHECK
FOR WATER
FLOW
BLOCKAGE
PRECOOL
PRODUCT
WARM
PRODUCT
WILL
RESULT IN
SLOW
RECOVERY
OPERATOR COMPLAINT IS:
“POOR OR SLOW PRODUCT RECOVERY
”
CHECK
SCRAPER
BLADES
IF WORN
REPLACE
CHECK
FREEZER
CAPACITY
RATING
DISPENSING
TOO LARGE
OF VOLUME
AT ONE TIME
IF PROBLEM PERSISTS
CONTACT H. C. DUKE & SON, INC. / ELECTRO FREEZE
SERVICE DEPARTMENT AT
800/755-4545
IF AIR
COOLED
CHECK FOR
AIR INTAKE/
DISCHARGE
BLOCKAGE
* ON FREEZERS WITH AUTO-FILL SYSTEM, BRIX FILL STATION TO PRODUCT SUPPLIERS RECOMMENDATION (MINIMUM 11% BRIX).
MOVE
OBSTRUCTION
OR MOVE
FREEZER
MUST HAVE
AT LEAST 6"
CLEARANCE
MOVE
OBSTRUCTION
OR MOVE
FREEZER MUST
HAVE AT LEAST
6" CLEARANCE
CHECK PRODUCT BRIX
ADJUST TO 11-13% BRIX*
CHECK PRODUCT BRIX
ADJUST TO 11-13% BRIX*
184262