![Electra ELAU-VCZ218-H11 Service Manual Download Page 98](http://html1.mh-extra.com/html/electra/elau-vcz218-h11/elau-vcz218-h11_service-manual_2378845098.webp)
Troubleshooting
Electrical Control System
97
For Console:
NO.
Malfunction
Running lamp
Timer lamp
Defrosting lamp
1
Open or short circuit of T1 temperature sensor
☆
X
X
2
Open or short circuit of T2 temperature sensor
X
X
☆
3
Communication malfunction between indoor and outdoor
units.
X
☆
X
4
Outdoor fan speed has been out of control
X
☆
O
5
Indoor EEPROM malfunction
☆
☆
X
6
IPM module protection
☆
X
☆
7
Open or short circuit of T3 or T4 temperature sensor or
Outdoor unit EEPROM parameter error
☆
☆
☆
8
Voltage protection
☆
☆
O
9
Inverter compressor drive protection
☆
◎
X
10
Indoor fan Speed has been out of control.
☆
O
☆
11
Mode conflict
☆
X
O
O(light) X(off)
☆
(flash at 5Hz)
◎
(flash at 0.5Hz)
Summary of Contents for ELAU-VCZ218-H11
Page 13: ...Indoor Units Indoor Units 11 Part 2 Indoor Units JKD Type 12 Light Commercial 22...
Page 20: ...Exploded View and Spare Part list 18 Indoor Units Exploded View of indoor unit ELSI JKD012 N11...
Page 22: ...Exploded View and Spare Part list 20 Indoor Units Exploded View of indoor unit ELSI JKD018 N11...
Page 36: ...Dimensions 34 Indoor Units...
Page 38: ...Service Space unit mm 36 Indoor Units 3 3 Console...
Page 40: ...Wiring Diagrams 38 Indoor Units ELSI OCD012 N11 ELSI QAD012 N11...
Page 41: ...Wiring Diagrams Light Commercial 39...
Page 44: ...Exploded View and Spare Part list 42 Indoor Units Exploded View of indoor unit ELSI OCD012 N11...
Page 46: ...Exploded View and Spare Part list 44 Indoor Units Exploded View of indoor unit ELSI QAD012 N11...
Page 52: ...Dimensions 50 Outdoor Units ELAU VCZ536 H11...
Page 56: ...Wiring Diagrams 54 Outdoor Units 4 Wiring Diagrams ELAU VCZ218 H11 ELAU VCZ327 H11...
Page 57: ...Wiring Diagr ams Outdoor Units 55 ELAU VCZ430 H11 ELAU VCZ536 H11...
Page 125: ...SERVICE MANUAL Multi Splits Series...