I02-118 User manual & maintenance guide
Version 04
(translation of the original manual)
of TLM 1000
Page
14
sur 25
5.2
Reassembly of the motor
Put the screw back on the new reducer.
Lubricate the shaft with copper grease.
For reassembly, follow the previous steps in
reverse order.
5.3
Changing the belt
–
Flat belt
Calculate the belt required length for a single unit:
[(L-160) x 2 + 490] x 0.97
L = total length of the transfer system, including the return.
Calculate the belt required length for a U-shape unit:
[(L-160) x 2 + 678] x 0.97
L = total length of the transfer system,
including the return.
Cut the first bevel.
Trace the point zero.
Cut the right length.
Cut the second bevel with the same
bevelling device.
Do not forget to take the length of the bevel into account when calculating the
length of the belt. The superposition of this length must be subtracted from the
total length.