Service manual
Service manual
Service manual
Service manual
Service manual
Service manual
Service manual
Service manual
Euro 2500
TX
82
Testing procedure:
1. ECR starts checking the clean FM area for any inconsist-
encies (misplaced records or errors).
2. A short summary is printed after the test ends.
5.11.3 Testing entire FM area
5.11.3 Testing entire FM area
This test combines both test mentioned above and thus tests
the integrity of entire FM space for records.
Procedure:
Look up “WHOLE FM area” in the FM integrity test menu or
enter code 2 and press
OK E
NTER
(
N
UM
E
NTER
).
Testing procedure:
1. First, this test checks the written records.
2. Then the test moves to check the unused space.
Integrity of the fiscal memory (FM) placed within the ECR is
a crucial part of ECR functionality. The Euro-2500TX offers
means to check the state of your FM module.
Look up “FM integr.test” in the service mode menu or enter
code 970 and press
OK E
NTER
(
N
UM
E
NTER
).
There are three modes for integrity testing: two of them are
basic tests, the last is a composite one. You can test the integ-
rity of used FM, integrity of unused (clean) FM, and you can
test both those areas, covering the FM in entirety.
5.11.1 Testing used FM area
5.11.1 Testing used FM area
This integrity test covers all records that have been written
into FM.
Procedure:
Look up “USED FM area” in the FM integrity test menu or en-
ter code 1 and press
OK E
NTER
(
N
UM
E
NTER
).
Testing procedure:
1. The ECR starts checking all written records, sequentially.
2. After checking their integrity, ECR prints out a summary.
5.11.2 Testing clean FM area
5.11.2 Testing clean FM area
The unused (clean) space of FM dedicated to records is sub-
ject to this test.
Procedure:
Look up “CLEAR FM area” in the FM integrity test menu or en-
ter code 3 and press
OK E
NTER
(
N
UM
E
NTER
).
900. Service mode
|
970.FM Integr.test
970.FM Integr.test >
1.USED FM area
********USED DATA INTEGRITY TEST********
UNIQUE NUMBER
Maximum rec.count
0001
Actual rec.count
0001
not valid
0000
PREREGISTRATIONS
Maximum rec.count
0008
Actual rec.count
0002
not valid
0000
CURRENCY CHANGES
Maximum rec.count
0004
Actual rec.count
0001
not valid
0000
RATE CHANGES
Maximum rec.count
0050
Actual rec.count
0001
not valid
0000
Z-DAILY REPORTS
Maximum rec.count
3000
Actual rec.count
0001
not valid
0000
MASTER RESETS
Maximum rec.count
0200
Actual rec.count
0003
not valid
0000
N.OF UNKNOWN RECORDS
0000
Printed testing output:
970.FM Integr.test |
2.CLEAR FM area
5.11 Testing the fiscal memory integrity
5.11 Testing the fiscal memory integrity
************************************
address 00020
BA B3 BC B0 B2 68 00 00
...
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
TEST
966.3
OK
Printed testing output: