Diagonal connection
One-side connection
Absorber-
surface
m
2
No. of
tubes
Minimum
flow rate
l/h
Nominal
flow rate
l/h
Maximum
flow rate
l/h
Minimum
flow rate
l/h
Nominal
flow rate
l/h
Maximum
flow rate
l/h
1,5 15 45
90
120
68
90
120
2 20 60 120 160
90
120
160
3 30 90 180 240 135
180
240
3,5 35 105 210
280
158
210
280
4 40 120 240 320 180
240
320
4,5 45 135 270
360
203
270
360
5 50 150 300 400 225
300
400
5,5 55 165 330
440
248
330
440
6 60 180 360 480 270
360
480
6,5 65 195 390
520
maximum 6 m² = 60 tubes permitted
7 70 210 420 560
7,5 75 225 450
600
8 80 240 480 640
9 90 270 540 720
10 100 300
600
800
11 110 330
660
880
12 120 360
720
960
Minimum flow rate with diagonal connection
30 l/m
2
h
Minimum flow rate with one-side connection
45 l/m
2
h
Nominal flow rate for both connection types
60 l/m
2
h
Maximum flow rate for both connection types
80 l/m
2
h
max. 120 tubes
max. 60 tubes
Design configuration and sizing
Expansion tank
related to water 20°C
-corresponds to
Antifrogen SOL HT 60°C