Planning Notes
Operating Limits
9
Pipes, tubes, and air ducts must be
kept as short as possible and routed in
such a way that pressure and heat loss
are minimized. Incorrectly or badly
installed or dimensioned pipes, tubes,
or air ducts may damage the heat
pump.
Area of Application
The following chart depicts the
application area of the air-water heat
pump AEROTOP T. Please consult the
performance overview for more
detailed operating specifications for
various heat pump models. The
temperature difference at the
condenser must be between
7 and 10°C.
Operating the heat pump is prohibited
if the following conditions exist:
•
Construction
drying
•
System/unit
used in unfinished
buildings
•
Windows
or exterior doors
unfinished and locked
These cases require the use of a
specific construction heating system.
Functional heating or surface-ready
heating with the heat pump acc. to
DIN EN 1264 is only permitted when
complying with these conditions.
General Information
The rated throughput values for
evaporator and condenser are
minimum values. Set points and
adjusted parameters may not fall below
these values to ensure the indicated
performance.
Furthermore, it must be noted that the
design of the heat pump concerning its
standard operation may not yield the
full extent of the required heat output.
The following notes must be observed
as well:
•
Comply with the corresponding
standards and rules of the
floor/screed
manufacturer!
•
Proper function is only ensured
with a correctly installed system
(hydraulics, electrical, settings)!
•
Deviations may damage the
floor/screed!
source inlet temperature [°C]
flo
w
t
emper
atu
re [°C]