Air Connections with Indoor Installation
AEROTOP T07-T35 with Noise Dampers (SI + SO) Corner Setup
41
AEROTOP T07 - 35 Corner Setup
The dimensions of the noise dampers
must be considered in addition when
placing heat pumps into a corner.
The heat pump can be placed in the
right or left corner. Air ducts are not
needed.
Required Accessories:
-
AIR IN wall setup kit
-
AIR OUT wall setup kit
-
SI Noise damper
-
SO Noise damper
1) The compliance with acoustic limit
values must be clarified by
customer.
AEROTOP T
Width Width Heigh
Dimensions With
Noise Dampers
Dimensions Of Both Cutouts,
Without Insulation
Minimal Dimensions,
Light Well
a
b
c
A
C a2 c2 d2 e2 x a3 c3 a4 c4
T07C,
T07 995 1525 650 1570 1225 950 600 640
860
635
1200
600 800 600
T10C, T10
1095
1575
750
1670
1325
1050 700
640 910 635 1200 600
1000
600
T12, T14,
T16
1195 1575 750 1770
1325 1150 700 640 1010 635 1200 600 1000 600
T20, T26
1195
1675
880
1770
1455
1150 830
740 930 635 1400 800
1200
800
T32,
T35
1295 1695 1000 1870 1575 1250 950 740
1140
635
1400 800 1200 800
•
Statistics to be checked by
customer If necessary wall must
be reinforced with PUR- insulation
elements. This must be considered
for the cutouts
The indicated cutouts apply only to the
accessories AIR IN and OUTLET wall
setup. The dimensions apply after all
tasks have been completed and refer
to finished floors.
2) Necessary outside insulation by
customer, minimal clearance of
light well must not be gone below.
3) Possible air short-circuit to be
prevented by customer.
4) Statistics to be checked by
customer
•
Possible air short-circuit to be
prevented by customer
•
Necessary outside insulation to
be installed by customer