background image

playback halts, leaving the DMX signal as it was at the 
moment of STOP. 
 

Loop 
 

Plays the show in repeat, starting again after finishing. The 
STOP function is as in PLAY. From PLAY one can change 
over to LOOP by depressing the LOOP button and back to 
PLAY again via PLAY. In this case the show will play till the 
end and stop then. 
 

Record Inhibit (Play Only) 
 

To protect the unit from re-recording a file by non qualified 
people the 

miniSTORE

 can be set to a safe mode via the dip 

switches at the back: 3 to 

 and 4 to 

. In this case only the 

PLAY, LOOP and STOP buttons are available. 
 

Control by external contact closure 
 

Instead of using the buttons at the front the 

miniSTORE

 can 

also be put into PLAY by an external contact. This setting can 
be made via the dip switches: 3 to 

 and 4 to 

. In this mode 

the front panel controls are inactive, so only change over to 
this mode in a STOP status. An external switch has to be 
connected to the DMX IN XLR between pins 2 and 1 or 3 and 
1. Closing this contact momentary puts the 

miniSTORE

 in 

PLAY, indicated by the PLAY led. The show plays till the end 
and comes in STOP. 
 

Automatic Play/Loop 
 

To have the 

miniSTORE

 constantly playing the show in LOOP 

after power on, dip switches 3 and 4 have to be set: 3 to 

 and 

4 to 

. Now the show is repeated as long as the unit is 

switched on and the front panel controls are not active. 

Summary of Contents for miniSTORE

Page 1: ...miniSTORE 512 channel DMX recorder playback Users Manual Software version 2 0 ...

Page 2: ...n the back panel there are 4 dip switches with the following preset functions Dipswitch 1 and 2 are used for setting number of channels and the framerate 1 2 Frames sec 40 33 25 12 A show with 12 moving lights with constant fading on 16 bit pan tilt CMY and dimmer will record up to 6 minutes 40fps A show with just a few changes might record up to hours Dipswitch 3 and 4 are used for setting the mo...

Page 3: ...will give a RECORD PAUSE condition indicated by an illuminated RECORD led and a blinking STOP led From here on one can go on with recording via RECORD again waiting for a DMX change or depressing RECORD again or stop by pressing STOP for the second time The DMX signal to be recorded has to be applied to the DMX IN connector In RECORD READY and RECORD this signal is looped through to the DMX OUT co...

Page 4: ...Control by external contact closure Instead of using the buttons at the front the miniSTORE can also be put into PLAY by an external contact This setting can be made via the dip switches 3 to and 4 to In this mode the front panel controls are inactive so only change over to this mode in a STOP status An external switch has to be connected to the DMX IN XLR between pins 2 and 1 or 3 and 1 Closing t...

Page 5: ...nal 3 pin Termination 120 Ohm in all modes except RECORD and RECORD READY when the input is looped through to DMX OUT External switch momentary contact from DMX IN pin 2 or 3 to GND pin 1 Memory 512kB static RAM with battery power Battery NiMH battery 70 mAh with trickle charge Hold time 120 days Power supply 115 230 Volt AC 3VA Changing the voltage is internal on the PCB No fuses protection is do...

Page 6: ...y ELC lighting Support contact support elclighting com Distributed by Worldwide distribution ANIMA LIGHTING LTD Stand 20 CH 1897 Le Bouveret Switzerland T Cell 0041 79 2104613 F 0041 86079 2104613 Email sales elclighting com URL www elclighting com ...