25
GAS CYLINDER CONNECTION
The connection between the hose con-
nector on the cooker and the regulator
of the gas cylinder must be made using
a 60 cm long flexible hose conforming
to applicable standards, and hose
clamps.
The connection hose must be inserted
in the hose support (fig. 11.4) and
pushed over the hose connectors to the
full depth.
IMPORTANT:
Only max 13 kg cylinders may be used
in the cylinder compartment, and they
must be positioned in such a way that
the regulator and shut-off cock are easily
accessible.
When changing the gas cylinder, do not
withdraw the hose from the hose
support G.
Installation and replacement of gas
cylinders must only be carried out by
qualified persons.
Fig. 11.4
Gas cylinder:
13 kg maximum
Hose length:
60 cm
Pressure regulator
Hose
clamp
Hose
clamp
Plug
G
Hose
support
Summary of Contents for EC 530