
43
TABLE FOR THE CHOICE OF THE INJECTORS - Cat:
I
3+
BURNERS
Nominal
Power
[kW]
Reduced
Power
[kW]
LPG
G30 28-30 mbar
G31 37 mbar
Ø injector
[1/100 mm]
Ring opening
[mm]
Auxiliary (A)
1,00
0,30
50
-
Semi-rapid (SR)
1,75
0,45
65
-
Triple-ring (TR)
3,50
1,50
95
-
Oven
6,20
1,30
120
8 (*)
Grill
4,65
-
107
Fully open (*)
(*) Reference value
AIR VENT NECESSARY FOR GAS COMBUSTION = (2 m
3
/h x kW)
BURNERS
Air necessary for combustion [m
3
/h]
Auxiliary (A)
2,00
Semi-rapid (SR)
3,50
Triple-ring (TR)
7,00
Oven
12,40
Grill
9,30
LUBRICATION OF THE GAS TAPS
In case of difficulty in the gas taps operation, call Service.
IMPORTANT
All intervention regarding installation maintenance of the appliance must be fulfilled
with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this
obligation.
GAS MAINTENANCE