Active Scan 250™
Gobos
©
Elation
®
- www.elationlighting.com - Active Scan 250™ Instruction Manual Page 15
©
Elation
®
- www.elationlighting.com - Active Scan 250™ Instruction Manual Page 16
Active Scan 250™
Lamp Replacement
Caution:
Always replace with the exact same type lamp, unless
otherwise specified by an authorized
©
Elation
®
service technician.
Replacing with anything other than the specified part can damage
your unit and will void your manufactures warranty.
Warning:
If you continue to blow lamps or the fuse, STOP using the
unit. Contact customer support for further instructions, you may have
to return the unit for servicing. Continuing to use the unit may cause
serious damage.
Lamp Replacement:
Caution! Never attempt to change the lamp
while the fixture is plugged in. Always disconnect the main power
and allow the unit ample time to cool before attempting to replace
the lamp. Lamp replacement has been made simple by incorporating
the use of a slide out lamp socket assembly that is retained by thumb
screws.
1. Be sure to follow the proper handling procedures that deal with
discharge lamps.
2. Unscrew and remove the two thumb screws at the rear of the
unit.
3. After removing the thumb screws, slide the lamp socket assembly
out.
4. Carefully remove the old lamp.
NEVER TOUCH A DISCHARGE
LAMP WITH YOUR BARE HANDS. NEVER DISCARD A
DISCHARGE LAMP IN THE TRASH. FOR PROPER DISPOSAL
INSTRUCTIONS, PLEASE REFER TO THE INSTRUCTIONS
INCLUDED WITH YOUR NEW DISCHARGE LAMP.
5. Replace the lamp with an exact match and reassemble in reverse
order.
For gobo replacement you need a small flat head screwdriver, and a
phillips screwdriver.
1. First, be sure that the power cord has been disconnected.
Do not open the unit, unless the power is off.
Allow the unit
ample time to cool, the inside can be very hot.
2, Unscrew and remove the 10 phillips screws. Three on each side of
the top cover, and four on the top of the cover.
3. Remove the top cover, to expose the gobo wheel.
4. With the small flat head screwdriver remove the fixation-ring that is
located on the lens side of the gobo. With the small screwdriver
gently pry the gobo out towards the lens. You can also use twee-
zers to gently pull the gobo out.
Active Scan 250™
Gobo Replacement
SPOT
1
7
6
5
4
3
2