OPERATIONAL MODE 2
ABSOLUTE/RELATIVE POSITION VISUALISER WITH TWO SETTABLE THRESHOLDS
FUNCTIONS
Absolute/relative visualisation (see par.Operating Specifications)
2 multiplying factors selectable by input (a different number of
decimals can be set for the second factor – see ‘Specific
setting’)
Count load
Display/count block
2 alarm outputs
MAIN DISPLAY PAGE
The display shows the value of the count record multiplied by the
set factor. Positive numbers are shown without sign indication,
while negative numbers are precedeed by the minus sign; values
exceeding -99999 are displayed without – sign, with the first digit
flashing.
ALARM THRESHOLDS
Two alarm thresholds, called positive and negative stroke ends,
can be set; they are enabled by comparison, respectively for
≥
and
≤
value than the count record.
Alarms can be enabled either in comparison with the absolute
record or with the relative record (see ‘Specific setting’).
OPERATING MODE
VALUE SETTING BY KEYBOARD
During the setting phase of a numerical value a dot flashes on the
right display side.
The key
R
sets the value to 0.
The
Arrow keys
modify the value.
The minus sign is obtained by pressing the
Arrow key 1
until
exceeding number 9. The max negative set is –99999
SETTING THE STROKE END VALUES (free setting)
The positive stroke end set phase is accessed by pressing the
key
P1
: the display shows
FC POS
followed by the current value.
The value is compared for
≥
with the absolute or relative count
record value to enable or disable output 1.
Modify the value with the
Arrow keys
, then press
P1
again to
store the new value and switch to the negative stroke end set
phase. The display shows
FC NEG
followed by the current value.
The value is compared for
≤
with the absolute or relative count
record value to enable or disable output 2.
Modify the value with the
Arrow keys
, then press
P1
again to
store the new value and switch back to the main display page.
VISUALISATION MODE SELECTION
Pressing
P2
switches the visualisation from the ABSOLUTE
RECORD to the RELATIVE RECORD and vice-versa. A dot
flashes on the display left side as the relative record is displayed.
RELATIVE RECORD RESET
Pressing the key
R
the display shows the flashing message
rESEt.
Press
R
again to reset the record or
F
to leave the phase.
INPUTS
CM78N-C02 is equipped with three inputs performing the
following operations:
IN1
= absolute value loading
IN2
= multiplying factor 1-2 selection
IN3
= count block or visualisation block
IN1: ABSOLUTE VALUE LOADING
On the input
IN1
closure front the LOAD value is entered into
the absolute count record.
IN2: MULTIPLYING FACTOR 1-2 SELECTION
Closing input
IN2
the display indication is switched from:
Displayed RECORD = COUNT x FACTOR 1
to
Displayed RECORD = COUNT x FACTOR 2
The number of displayed decimals corresponds to the setting
‘
Factor 2 decimals’
(see ‘
Specific setting’
). The LOAD and
STROKE ENDS values are also converted automatically.
IN3: VISUALISATION/COUNT BLOCK
If the
count block
function was selected, the pulses count is
stopped by closing input
IN3.
If the
visualisation block
function was selected, the display update
of the pulses count is suspended when closing input
IN3
.
The input pulses count goes on and the updated value is
displayed when input
IN3
is opened again.
OUTPUTS
The instrument is equipped with 2 alarm signal outputs.
OUT 1
= Positive stroke end
OUT 2
= Negative stroke end
PARAMETERS SETTING
Press the key
F
and, when the display shows
Ch.Set,
digit the
key sequence
P2 F P1
within 5 seconds to access the
parameters setting phase.
During the setting phase of a numerical value a dot flashes on the
right display side.
The key
R
sets the value to 0.
The
Arrow keys
modify the value.
The minus sign is obtained by pressing the
Arrow key 1
until
exceeding number 9. The max negative set is –99999.
Press
F
to confirm the set value and switch to the following
parameter.
PARAMETERS LIST
Load (setting under constants key)
The display shows
LoAd
followed by the current value.
The LOAD value is stored into the count record by closing input
IN1
.
Output 1 Excitation Time (for selection: timed pulse outputs)
The display shows
tout 1
followed by the current value of output
1 excitation time expressed in seconds.
Default value 0.3 S.
Mimimum setting 0.1 S, max setting 25.0 S.
Output 2 Excitation Time (for selection: timed pulse outputs)
The display shows
tout 2
followed by the current value of output
2 excitation time expressed in seconds.
Default value 0.3 S.
Mimimum setting 0.1 S, max setting 25.0 S.
Stroke ends (setting under constants key)
The display shows
FC POS
. followed by the current value.
The value is compared with the count record value to enable or
disable output 1.
After confirming the positive end stroke value the display shows
FC nEg.
followed by the current value.
The value is compared with the count record value to enable or
disable output 2.
Multiplying Factors 1 – 2
The display shows
FAtt.n
followed by the current value. Factor
1 is used when
IN2
is open, Factor 2 is used when
IN2
is closed.
After confirming the second value the display switches to the
main page.
Factors range values: 0.01000/9.99999.
Vv CM78N_C02_ING.doc 28/05/2009 page 6/6