BASIC SETTING 

CM78N-C02 can be configured by the user to fit to different operational modes. 
The configuration is performed as follows: 
Press the key 

to access the configuration phase. The display will show 

Ch.SEt.

 

Digit the key sequence 

R – Arrow 2 -  Arrow 4

 – within 5 seconds. The display will 

show: 

F:XXXXX    

Now you can enter the configuration code. 

The configuration code is composed according to the table hereunder: each code 
position corresponds to a column of the table; each option corresponds to a line of 
the table. The setting is made by pressing the arrow key corresponding to the digit to  
be modified until reaching the number corresponding to the required function.  
 

 

F.XXXXX   BASIC SET-UP 

 

OPERATING MODE 

Count type 

Functional 

Inputs Polarity 

Decimal Digits 

Input IN3 
Function 

Position visualiser 

Bidirectional x 4 

NPN 

No one 

Count block 

Position visualiser with 

alarms 

Bidirectional x 1 

PNP 

Display block 

Absolute/relative position 

visualiser with alarms 

Monodirectional 

up-counter 

 2  

 Monodirectional 

down-counter 

 3  

SETTING CONFIRMATION 

After entering the required configuration code press

 F 

to confirm and access the setting of the 

operating functions

 specific for the 

chosen operational mode. 

SPECIFIC SETTINGS 

This phase can also be accessed pressing

  F 

and, when the display shows 

Ch.Set,

 entering the key sequence 

Arrow 1, Arrow 6, 

Arrow 2. 

The setting is made by pressing the arrow key corresponding to the digit to be modified until reaching the number corresponding to the 
required function.  
According to the chosen operational mode you can meet  three possible situations: 

OPERATIONAL MODE 0 

 C.XX 

– 

OPERATIONAL MODE 0 – SPECIFIC SET-UP

 

 

LOAD BY KEYBOARD 

LOAD BY INPUT 

Disabled 

On the closure state 

Enabled 

On the closure front 

 

OPERATIONAL MODE 1 

 C.XXX 

– 

OPERATIONAL MODE 1 – SPECIFIC SET-UP

 

 

LOAD BY KEYBOARD 

RELAY OPERATION 

END STROKE SETTING 

LOAD SETTING 

Disabled Steady 

outputs 

Free 

Free 

Enabled 

Pulse timed outputs 

Under set-up key 

Under set-up key 

 

 

Under constants key 

Under constants key 

 

OPERATIONAL MODE 2 

 C.XXXX 

– 

OPERATIONAL MODE 2 – SPECIFIC SET-UP 

 

COMPARING MODE  FACTOR 2 DECIMALS

RELAY OPERATION 

STROKE END SETTING

Absolute record 

No one 

Steady outputs 

Free 

Relative record 

Timed pulse outputs 

Under set-up key 

 

 

Under constants key 

 3    

 

SETTING CONFIRMATION 

After entering the required set-up press

 F 

to confirm. If the chosen selection involves the parameters entering  under SET-UP key the 

parameter setting phase is accessed; otherwise you switch to the main display page. 

 
 

 

Key Arrow 1 

Summary of Contents for CM78N

Page 1: ...starting the configuring operations MANUAL STRUCTURE Pages 1 to 3 of the present manual relate to the instrument general working mode Pages 4 to 6 relate to the operating way of each operational mode The paragraph Operating specifications page 2 gives details about the instrument configurations SUMMARY page Technical specifications 1 Introduction 1 Operational modes description 1 Operating specifi...

Page 2: ...unted pulses in the required measuring unit The multiplying factor value can range between 0 01 and 9 99999 MULTIPLYING FACTOR CALCULATION To define the multiplying factor value it is necessary to know the following data A value that must be displayed for each encoder rotation The value must be expressed in the resolution unit used for the visualisation see the example B number of the encoder puls...

Page 3: ...ng of the operating functions specific for the chosen operational mode SPECIFIC SETTINGS This phase can also be accessed pressing F and when the display shows Ch Set entering the key sequence Arrow 1 Arrow 6 Arrow 2 The setting is made by pressing the arrow key corresponding to the digit to be modified until reaching the number corresponding to the required function According to the chosen operati...

Page 4: ...er key cancels the operation INPUTS OUTPUTS The instrument is equipped with three inputs performing the following operations IN1 load see paragraph specific settings IN2 mm inch display switch IN3 count block or visualisation block see par basic settings Outputs are not used in this operational mode LOAD BY INPUT Closing input IN1 the LOAD value is displayed If the function load on the closure sta...

Page 5: ...g operations IN1 load IN2 mm inch display switch IN3 count block or visualisation block IN1 LOAD BY INPUT Closing input IN1 the LOAD value is displayed If the function load on the closure state was selected the pulses count is blocked until input IN1 is opened again IN2 mm inch CONVERSION Closing inpunt IN2 the display indication is switched form mm to inch The inch displayed value has one decimal...

Page 6: ...N3 count block or visualisation block IN1 ABSOLUTE VALUE LOADING On the input IN1 closure front the LOAD value is entered into the absolute count record IN2 MULTIPLYING FACTOR 1 2 SELECTION Closing input IN2 the display indication is switched from Displayed RECORD COUNT x FACTOR 1 to Displayed RECORD COUNT x FACTOR 2 The number of displayed decimals corresponds to the setting Factor 2 decimals see...

Page 7: ......

Reviews: