TROUBLESHOOTING
03/2022
73
NP-DK50 2V 50, 2x2V 110-AD-A-1_03-2022
Entrust a specialised company to sort and dispose of waste.
Worn out components have no negative environmental impact.
TROUBLESHOOTING
Risk of electric shock.
Before interfering with the equipment, first disconnect it from the mains
(remove the power socket).
Working with pressurised pneumatic components poses a risk of injury.
Before interfering with the equipment, vent the air tank and the compressed air
system to zero pressure.
Troubleshooting may only be performed by a qualified service technician.
Damage to the safety valve could cause pressure to rise to hazardous levels.
Never adjust a safety valve.
Malfunction
Possible cause
Solution
Compressor does
not switch on
No voltage in the pressure switch
Check voltage in socket
Check circuit breaker switch
–
switch to position switched-
on „I“
Loose conductor from terminal -
repair
Check electrical cord
– replace
defective cord
Motor winding failure, damaged
thermal protection
Replace motor or windings
Capacitor failure
Replace capacitor
Seized piston or other rotating part
Replace damaged components
Pressure switch does not switch
Check function of pressure switch
Compressor often
switches on
Air leakage in pneumatic system
Check pneumatic system
– seal
loose connections
Non-return valve (SV) leakage
Clean non-return valve, replace
seals, replace non-return valve
Large volume of condensed liquid in
pressure tank
Drain condensed liquid
Low compressor capacity
Check time of filling the air tank
Low pressure in
the air tank
(compressor
running constantly)
High air consumption of supplied
equipment
Decrease air consumption
Use compressor with higher
capacity
Leakage in pneumatic system
Check pneumatic system
– seal
loose connections
Low capacity of the pump
Clean / replace the pump
Pump failure
Clean / replace the pump
Summary of Contents for DK50 2V/50/M
Page 1: ...N VOD NA POU ITIE SK USER MANUAL EN BENUTZERHANDBUCH DE...
Page 2: ......
Page 4: ...CONTENTS 5 INHALT 76 OBSAH 146...
Page 18: ...PRODUCT DESCRIPTION NP DK50 2V 50 2x2V 110 AD A 1_03 2022 18 03 2022 B DK50 2x2V 110S M...
Page 89: ...PRODUKTBESCHREIBUNG 03 2022 89 NP DK50 2V 50 2x2V 110 AD A 1_03 2022 B DK50 2x2V 110S M...
Page 158: ...POPIS V ROBKU NP DK50 2V 50 2x2V 110 AD A 1_03 2022 158 03 2022 Obr 4 Skrinka A DK50 2V 50S M...
Page 159: ...POPIS V ROBKU 03 2022 159 NP DK50 2V 50 2x2V 110 AD A 1_03 2022 B DK50 2x2V 110S M...
Page 218: ......
Page 219: ......
Page 220: ...NP DK50 2V 50 2x2V 110 AD A 1_03 2022 112000519 000...