41
6.
TECHNICAL SPECIFICATIONS
•
CONNECTIONS
Connection between scanner and control panel
Supply voltage
Output for direct motor lock connection (screw clamp)
Relay output via main plug
RS485 interface via main plug
Potential free gate input via main plug
Power supply (AC or DC) via main plug
•
MEMORY
99 fingers possible
No loss of data after power failure
•
SECURITY
Coupling between scanner and control panel
Extremely low rate of false identification (FAR 1x 10
-6
for FRR 1,4x10
-2
)
•
ELECTRICAL DATA
Input voltage:
8V – 24V AC
8V – 30V DC
Input capacity:
~ 1W (without motor lock)
Switching capacity:
30V 2A
Motor lock capacity:
30V 2A
•
AMBIENT CONDITIONS
Temperature range:
-40°C … +85°C
Protection category:
Control panel IP41 (when mounted)
Finger scanner IP43
•
SPEED
Recognition time 1s to 4s
(depending on the amount of stored fingers and on operation)
Enrolment time ~4s per finger