6.6 Adapting the monitor using Force Mode
30
CuratOR LX491W
Instructions for Use, 02/2018
Determine start values using auto function
The following commands can be used to trigger automatic determination of the timing data,
and provides rough approximation of the applied timing.
1. Open a test pattern with a clearly defined border (e.g., SMPTE image).
2. Open the "Force Mode" menu in the OSD.
3. Set "Mode" to "Start".
4. The start values are determined when you select "Execute function…"
Note:
The timing data are only entered into memory with the "Execute function" com-
mand, and the image is then displayed with the new parameters.
After the "Execute function…" "Mode" switches to "Active" and you can optimize the start
values.
Entering known data
If some of the timing data are known they can be entered after determining the start values
in order to simplify the subsequent steps.
If the resolution is known for example, it can be used for the approximation of "Total horizon-
tal lines". In this case, "Total horizontal lines" has to be greater than "Horizontal Resolution".
If "Total horizontal lines" is less than "Horizontal Resolution" during setting, that latter has to
be reduced. A larger "Horizontal Resolution" can result in the image being split vertically.