LC-XG300/250_ Basic Serial Command Specifications
Ver.
Rev.A
Page
24
7.3.11. “81”[CR]
Status: Standby after Cooling down due to lamp failure
The projector has recovered from Lamp Failure status. When the projector enters
Standby mode after Cooling down operation invoked due to lamp failure, it returns
“81”[CR]. This indicates the status turns to Standby due to lamp failure.
This status continues until the next operation is started; when Power ON is executed,
the projector clears the information of Lamp Failure and normal operation starts.
7.4. Input Mode Read Command
Command “CR1”
[CR]
Detail
Get the selected Input No.
Acceptable “%1”
[CR]
%1
”1” = Input 1 is selected
”2” = Input 2 is selected
”3” = Input 3 is selected
”4” = Input 4 is selected
Response
Unacceptable “?”
[CR]
7.5. Lamp Time Read Command
Command “CR3”
[CR]
Detail
Get the total lamp running hours (corresponding value).
Acceptable “%1”
[CR]
%1
Shows the time period with 5 digits numbers.
Example
:
“00410”[CR]
・・・・
shows 410 hours
Response
Unacceptable
“?”
[CR]
7.6. Setting Read Command
Command “CR4”
[CR]
Detail
Get the screen setting status such as Ceiling / Rear.
Acceptable “%1”
[CR]
%1
“11”[CR] = Normal Screen Setting
“10”[CR] = Picture is top/bottom reversed.
(Status: Rear
&
Ceiling ON)
“01”[CR] = Picture is left/right reversed. (Status: Rear ON)
“00”[CR] = Picture is top/bottom and left/right reversed.
(Status: Ceiling ON
)
Response
Unacceptable “?”
[CR]