LC-XG300/250_ Basic Serial Command Specifications
Ver.
Rev.A
Page
23
7.3.5. “10” [CR]
Status: Power Failure
When the power supply voltage inside the projector reaches abnormal status, the
projector is automatically turned off. The projector returns “10”[CR], which shows it
moves to Power OFF status due to power failure. Fan also stops unlike Cooling Down
status.
7.3.6. “28” [CR]
Status: Cooling Down in process due to Temperature Anomaly
When the inside temperature is out of the operating temperature, it automatically starts
Cooling Down. Response for this status is “28”[CR].
Even if the temperature decreases during this process, Cooling Down is executed.
7.3.7. “88”[CR]
Status: Coming back after temperature anomaly
When the status moves to Standby after Cooling Down due to temperature anomaly, it
returns “88” [CR].
This shows that the status turns to Standby because of abnormal temperature.
This status maintains until next operation is done. When Power On is executed, the
information of temperature anomaly is canceled and normal operation is executed.
7.3.8. “24”[CR]
Status: Power Save / Cooling Down in process
Power management function in Setting menu works and the status goes to Power Save
/ Cooling Down.
During this time, Functional Execution Commands are invalid (not executed).
This status moves to Power Save at set hours after the operation of Cooling Down.
Status
:
No signal
Power Save / Cooling Down Power Save
Response
:
“00”
“24”
“04”
5 minutes with no signal After about 90 sec.
7.3.9. “04”[CR]
Status: Power Save
This shows that it moves to Power Save status by Power management function in
Setting menu.
7.3.10. “21”[CR]
Status: Cooling down in process after OFF due to lamp failure
When the projector status is turned off due to lamp failure, it automatically starts Cooling
down. The projector returns “21”[CR]. “21”[CR] has been kept during Cooling down
operation.