background image

LC-XG300/250_ Basic Serial Command Specifications   

                                                                                     

 

 

 Ver. 

Rev.A 

Page 

23 

 

7.3.5. “10” [CR] 

Status: Power Failure 

When the power supply voltage inside the projector reaches abnormal status, the 

projector is automatically turned off. The projector returns “10”[CR], which shows it 

moves to Power OFF status due to power failure. Fan also stops unlike Cooling Down 

status.

 

7.3.6. “28” [CR] 

Status: Cooling Down in process due to Temperature Anomaly 

When the inside temperature is out of the operating temperature, it automatically starts 

Cooling Down. Response for this status is “28”[CR].   

Even if the temperature decreases during this process, Cooling Down is executed. 

7.3.7. “88”[CR] 

Status: Coming back after temperature anomaly 

When the status moves to Standby after Cooling Down due to temperature anomaly, it 

returns “88” [CR]. 

This shows that the status turns to Standby because of abnormal temperature. 

This status maintains until next operation is done. When Power On is executed, the 

information of temperature anomaly is canceled and normal operation is executed. 

7.3.8. “24”[CR] 

Status: Power Save / Cooling Down in process 

Power management function in Setting menu works and the status goes to Power Save 

/ Cooling Down. 

During this time, Functional Execution Commands are invalid (not executed). 

This status moves to Power Save at set hours after the operation of Cooling Down.

 

 

Status

: 

No signal             

Power Save / Cooling Down                        Power Save 

Response

: 

“00” 

   

                                “24” 

                                          “04” 

         

 

5 minutes with no signal                After about 90 sec. 

 

7.3.9. “04”[CR] 

Status: Power Save 

This shows that it moves to Power Save status by Power management function in 

Setting menu.

 

7.3.10. “21”[CR] 

Status: Cooling down in process after OFF due to lamp failure 

When the projector status is turned off due to lamp failure, it automatically starts Cooling 

down. The projector returns “21”[CR].  “21”[CR] has been kept during Cooling down 

operation.

   

 

Summary of Contents for LC-XG250

Page 1: ...BASIC SERIAL COMMAND SPECIFICATIONS LC XG300 250 Ver 0 01 TENTATIVE...

Page 2: ...WER OFF Command 11 6 8 INPUT 1 Command 11 6 9 INPUT 2 Command 11 6 10 INPUT 3 Command 12 6 11 NETWORK Command 12 6 12 VOLUME Command 12 6 13 VOLUME Command 12 6 14 SOUND MUTE ON Command 12 6 15 SOUND...

Page 3: ...FREEZE OFF Command 18 6 46 ZOOM Command 18 6 47 ZOOM Command 18 6 48 FOCUS Command 18 6 49 FOCUS Command 18 6 50 INPUT 1 Analog RGB Command 18 6 51 INPUT 1 SCART Command 19 6 52 INPUT 1 DVI PC Digital...

Page 4: ...LC XG300 250_ Basic Serial Command Specifications Ver Rev A Page 3 7 8 Lamp Mode Read Command 25...

Page 5: ...mputer 2 Serial Interface Specifications 2 1 Transfer Specifications Item Specifications Synchronous system Asynchronous Transmission Speed 9600 19200 Data Length 8 bit Parity N A Stop Bit 1 Flow Cont...

Page 6: ...al time of 500ms at least after receiving a response 3 7 When a command is issued before receiving a response the function is not executed properly except when there is no Response for more than 5 sec...

Page 7: ...E C08 NETWORK C28 ON START Enable C09 VOLUME C29 ON START Disable C0A VOLUME C2A POWER MANAGEMENT READY C0B SOUND MUTE ON C2B POWER MANAGEMENT OFF C0C SOUND MUTE OFF C2C C0D VIDEO MUTE ON C2D C0E VIDE...

Page 8: ...C ADJ C4A FOCUS C8A PRESENTATION TIMER C4B FOCUS C8B C4C C8C C4D C8D C4E C8E KEYSTONE C4F C8F KEYSTONE C50 INPUT 1 Analog RGB C90 C51 INPUT 1 Scart C91 C52 INPUT 1 DVI PC Digital C92 C53 INPUT 1 DVI A...

Page 9: ...ifications Ver Rev A Page 8 5 Status Read Command Table Command Item Memo CR0 Status Read CR1 Input Mode Read CR2 CR3 Corresponding Lamp Time Read CR4 Setting Read CR5 CR6 Temp Read CR7 Lamp Mode Read...

Page 10: ...command pipelining Volume Zoom etc the performance is the same as that of the remote control 6 2 1 System issue any command every 100 ms 6 2 2 When receiving the appropriate command the function is e...

Page 11: ...ted C01 POWER OFF C02 POWER OFF Countdown is terminated C46 ZOOM C47 ZOOM C4A FOCUS C4B FOCUS C5D LENS SHIFT UP C5E LENS SHIFT DOWN C5F LENS SHIFT LEFT C60 LENS SHIFT RIGHT Cooling Down in process NON...

Page 12: ...function as ON STAND BY button of the projector and remote control Once this command is sent Power OFF is displayed If this command is sent again while it is displayed Power OFF is executed When sendi...

Page 13: ...ptable ACK CR Response Unacceptable CR 6 12 VOLUME Command Command C09 CR Detail Volume Up This command operates the same way as VOLUME button of the projector and remote control Acceptable ACK CR Res...

Page 14: ...for No Show OFF Acceptable ACK CR Response Unacceptable CR 6 17 VIDEO MUTE OFF Command Command C0E CR Detail Video Mute OFF This command works the same way as NO SHOW button of remote control for No...

Page 15: ...esponse Unacceptable CR 6 23 BRIGHTNESS Command Command C20 CR Detail Brightness of User Control 1 Acceptable ACK CR Response Unacceptable CR 6 24 BRIGHTNESS Command Command C21 CR Detail Brightness o...

Page 16: ...d retained regardless of Power OFF ON Acceptable ACK CR Response Unacceptable CR 6 30 ON START Cancel Command Command C29 CR Detail Disable Power ON Start This status is stored in EEPROM and retained...

Page 17: ...remote control Acceptable ACK CR Response Unacceptable CR 6 35 D ZOOM Command Command C31 CR Detail Enter Digital Zoom mode and reduce image size This command works the same way as D ZOOM button of th...

Page 18: ...mand Command C3C CR Detail Move up the Pointer of On Screen Display This command operates the same way as button of the projector Acceptable ACK CR Response Unacceptable CR 6 42 POINTER DOWN Command C...

Page 19: ...d image size This command works the same way as ZOOM button of the projector Acceptable ACK CR Response Unacceptable CR 6 48 FOCUS Command Command C4A CR Detail Adjust on screen focus by making focal...

Page 20: ...cceptable CR 6 53 INPUT 1 DVI AV HDCP Command Command C53 CR Detail Select DVI AV HDCP input in Input 1 Acceptable ACK CR Response Unacceptable CR 6 54 LENS SHIFT UP Command Command C5D CR Detail Move...

Page 21: ...MER Command Command C8A CR Detail Execute Presentation Timer This command works the same way as P TIMER button of the remote control Acceptable ACK CR Response Unacceptable CR 6 60 KEYSTONE Command Co...

Page 22: ...ceives the appropriate command it returns a character line as the required data Required Data CR Required Data A character line See Basic Status Read Command Table 7 1 3 When the received data cannot...

Page 23: ...us is Standby Status Read Commands are always acceptable but Functional Execution Commands are not acceptable except POWER ON Command 7 3 3 40 CR Status Countdown in process When Display in Setting Me...

Page 24: ...e status turns to Standby because of abnormal temperature This status maintains until next operation is done When Power On is executed the information of temperature anomaly is canceled and normal ope...

Page 25: ...nd Command CR1 CR Detail Get the selected Input No Acceptable 1 CR 1 1 Input 1 is selected 2 Input 2 is selected 3 Input 3 is selected 4 Input 4 is selected Response Unacceptable CR 7 5 Lamp Time Read...

Page 26: ...the temperature goes down to the first character becomes instead of a space like 05 5 CR When no temperature data can be returned due to hardware problems the first character becomes E like E00 0 CR...

Reviews: