LC-XG300/250_ Basic Serial Command Specifications
Ver.
Rev.A
Page
25
7.7. Temp Read Command
Command “CR6”
[CR]
Detail
Get the temperature data inside the projector.
With some temperature sensors installed in the projector, it is possible to get all
the temperature at once.
Acceptable “%1_%2_%3”
[CR]
%1
%2
%3
%1
=
Temperature of sensor 1
%2
=
Temperature of sensor 2
%3
=
Temperature of sensor 3
Temperature data is shown as “00.0”.
When the temperature goes down to -, the first character
becomes “-” instead of a space, like “-05.5” [CR].
When no temperature data can be returned due to hardware
problems, the first character becomes “E” like”E00.0” [CR].
When several temperature sensors are equipped, Responses are
returned continuously.
“_31.5 _ _
35.2
_ _33.4”[CR]
The first data is sensor 1, then one space, and the data of sensor
2 follows.
Response
Unacceptable
?
[CR]
7.8. Lamp Mode Read Command
Command “CR7”
[CR]
Detail
Get lamp mode.
The projector with single lamp get ON/OFF status of the lamp.
Acceptable “%1”
[CR]
%1
“00”[CR] = Lamp is OFF.
“01”[CR] = Lamp is ON.
Response
Unacceptable
?
[CR]