LC-XG300/250_ Basic Serial Command Specifications
Ver.
Rev.A
Page
11
6.5. POWER ON Command
Command “C00”
[CR]
Detail
Power ON
When already Power is ON, nothing is done.
When sending this command during Countdown in process, Countdown is
terminated.
Acceptable [ACK]
[CR]
Response
Unacceptable
?
[CR]
6.6. POWER OFF Command
(
Quick Power OFF
)
Command “C01”
[CR]
Detail
Power OFF (Standby)
When Power is OFF with ON-OFF button of the projector and remote control,
“Power OFF?” is displayed. However, as soon as this command is sent, Quick
Power OFF is executed.
Acceptable [ACK]
[CR]
Response
Unacceptable
?
[CR]
6.7. POWER OFF Command
Command “C02”
[CR]
Detail
Power OFF (Standby).
The command operates the same way Power OFF function as ON/STAND-BY
button of the projector and remote control.
Once this command is sent, “Power OFF?” is displayed. If this command is sent
again while it is displayed, Power OFF is executed.
When sending this command during Countdown, Countdown is terminated.
Acceptable [ACK]
[CR]
Response
Unacceptable
?
[CR]
6.8. INPUT 1 Command
Command “C05”
[CR]
Detail
Select Input 1.
This command operates differently from “Input 1” key of the remote control. When
INPUT 1 is already selected, this command does not execute the source
switching. (Just for switching to Input 1)
Acceptable [ACK]
[CR]
Response
Unacceptable
?
[CR]
6.9. INPUT 2 Command
Command “C06”
[CR]
Detail
Select Input 2.
This command operates differently from “Input 2” key of the remote control. When
Input 2 is already selected, this command does not execute the source switching.
(Just for switching to Input 2)
Acceptable [ACK]
[CR]
Response
Unacceptable
?
[CR]