Preparation: Slide the clamping
sleeve over the cable.
(A)
Mount the RJ45 connector on the
cable. Remove the release tab of
the RJ45 plug.
(B)
Insert collet chuck, aligning the
opening on the contact side of the
RJ45 connector
(C)
Slide clamping sleeve over RJ45
connector.
Connect the power cable and establish the Ethernet connection between the IoT Box and your PLC
system. This completes the commissioning on the hardware side.
The IoT Box has a radio range of up to 500m in the open field. Obstacles between the scales and the
IoT Box, such as walls, can impair the range accordingly. Therefore, if possible, select a location with
a clear view of the connected scales.
Two IP addresses are preset. The IP address 192.168.0.1 is used for PLC communication. For the
internal communication of Netscale the IP address 192.168.0.2. is used. If other IP addresses should
be used, please contact your EHP representative. The IoT Box can be adjusted before delivery.