Only relevant for customer-specific applications.
The preconfigured data log has the following data format (28 bytes):
1.
S
Start signal
2.
0
1
2
3
4
No comma
One decimal place
Two decimal places
Three decimal places
Four decimal places
(e.g. 19520)
(e.g. 1952.0)
(e.g. 195.20)
(e.g. 19,520)
(e.g. 1.9520)
3.
Blank (20H)
+
-
No sign
Plus
Minus
4.
Digit 5
Ten-thousandths digit of the weight
5.
Digit 4
Thousands digit of the weight
6.
Digit 3
Hundreds digit of the weight
7.
Digit 2
Decimal place of the weight
8.
Digit 1
Units digit of the weight specification
9.
B
N
Scale tare OFF (gross weight)
Scale tare ON (net weight)
10.
E
1
2
Single range scale
in area I
in area II
11.
0
1
No standstill
Standstill
12.
0
1
2
3
4
5
6
7
8
A
X
E
C
No key is pressed on the handheld transmitter
Key 2 (
Print key
)
Key 4 (
Add- key
)
Key 6 (
Total key
)
Scale was switched off manually
Scale was switched off by automatic switch-off function
Reception disturbance
Test
13.
V
H
L
Scale battery charged
Scale battery - forewarning
Scale battery - Discharged/ Empty
14.
(1 - 99)
Digit 1 of the scale number
15.
(1 - 99)
Digit 2 of the scale number
16.
(X)
no setpoint =0, setpoint 1 =8
Setpoint 2=4, Setpoint 3=2
Setpoint 4=1 Values of the setpoints that overlap are added
together.