11
Power supply
Power connection
Earthed power socket via IEC power plug
Supply voltage
230 V
ac
, 50 Hz
Design basis for supply
cable
Leg Press M9: 6 A
all others: 4 A
Max. momentary current
consumption
Leg Press M9: 16 A
all others: 8 A
Recommendation
Protect the supply cable for two eGym strength machines via
a Type B 16 A circuit breaker or a gG/gL 16 A safety fuse – the
leg press requires a separate 16 A fuse
Leakage current
≤
3,5 mA per eGym strength machine
Protection with AC/DC-sensitive Type B residual current operated
circuit breaker I
n
=
30
mA
Recommendation
Max. four eGym strength machines per RCCB
Recommendation
Doepke
dfs
4 B SK
e. g.
dfs
4 040-2/0,03-B SK
e. g.
dfs
4 040-4/0,03-B SK
A Type B+ RCCB is not recommended as this has increased high frequency sensitivity.
Internet connection
For the dynamic assignment of IP-addresses, the DHCP-server needs to be activated in the
available network, and the pool of „DHCP leaser“ must be large enough
(recommended: >100). Firewalls and MAC filtering are not supported and may not be inter-
posed.
Band width: min. 5 Mbit/s download, min. 1 Mbit/s upload
Option 1:
LAN
Option 2:
WLAN
Recommendation
Set up router within visual range; maximum
10 m; the by eGym provided router must be
used.
Plan a 1,5 m network cable in the Gym
strength machine interior
Plug socket
Address space:
10.8.0.0 – 10.8.255.255
Address space:
10.8.0.0 – 10.8.255.255
192.168.150.0 – 192.168.150.255