EFX MK-VI Audio Controller Owner’s Manual
26
XPDL
Source - Selects whether an expression pedal or
two foot-switches is connected to the
XPDL jack.
Device - Selects the device to receive this control
change message.
CC# - Selects the controller number to be sent.
Max.Value - Highest controller value that the XPDL can send when its pedal is moved.
Min.Value - Lowest controller value that the XPDL can send when its pedal is moved
Rate - Selects the minimum time interval between XPDL CCs.
Tempo CC
Some MIDI devices receive MIDI Control Change, not
MIDI TIME CLOCK, as the tempo message. This page
lets you set the MIDI Control Change as a tempo for
these units.
Device - Selects the device to receive this control
change message.
CC# - Selects the controller number to be sent.
On.Value/Off.Value - Divide the quarter note into two and send the ON value first and OFF value second.
Devices
EFX MK-VI can set up to 16 devices. 16 devices are displayed as Device01 to Device16, each of which can be
assigned a Port, MIDI channel, PC# Offset and Maximum Scroll PC#.
Port - Selects the MIDI Port(MIDI Out or USB) to be sent to each device.
Channel - Selects the MIDI channel to be sent to each device.
PC# Offset - Selects whether to display the minimum value of the program number as 0 or 1.
Max.Scr.PC# - Selects the maximum value when increasing or decreasing program numbers