www.efd-inc.com [email protected]
USA & Canada 800.556.3484 44 (0) 1582 666334 Asia & China: +86 (21) 3866 9006
Sales and service of EFD
®
dispensing systems are available worldwide.
Pin 7:
PS+
24VDC Power :
This pin will provide 24 VDC, 100mA power to an external load.
Pin 8:
Alarm In
Alarm Input:
This pin senses a relay or switch closure. Once a closure is sensed, the dispenser will
display the Input Alarm Indicator and prevent any further dispense cycles from initializing. An internal
1.2K resistor will limit the Alarm Input signal current to 20mA or less. This signal can be disabled in the
Alarm Options LCD screen.
Pin 9:
Alarm Out+
Alarm :
This is the positive input signal for the Alarm Output solid state switch.
APPENDIX A
I/O Connector
Pin Descriptions
Ultimus V DIO
Pin 5: PS+
Common
Pin 6: CC Init
1.2K
Proximity Sensor
External Relay
Pin 12: PS-
Dispense Cycle Control with Contact Closure Initiate,
NPN Proximity Sensor, and an External Relay
Vcc
Ultimus V DIO
Pin 5: PS+
Common
Pin 8:
Alarm Input
1.2K
Proximity Sensor
External Relay
Pin 12: PS-
Alarm Input, NPN Proximity Sensor,
and an External Relay
Vcc
31