2010ECL-NYC SERIES SIGNAL MONITOR
OPERATIONS MANUAL
Eberle Design Inc.
Page 21
To program a NON-CONFLICTING (permissive) channel pair, remove the appropriate diode
from the program card.
Example: If channel 2 Green or Yellow is permissive with channel 6 Green or
Yellow, remove the diode labeled "2-6".
If the Program Card is removed or not seated properly in the edge connector, the Signal
Monitor will enter the fault mode causing the Output relay contacts to close and enabling the
Stop-Time output to the controller. The PCA indicator will illuminate to indicate this condition.
A manual Reset is required after the Program Card is properly seated.
4.3.1 YELLOW DISABLE JUMPERS
To DISABLE sensing of a Yellow signal on a channel, solder a wire jumper between the hole
pairs on the Program Card labeled for that channel. When the jumper is installed the monitor
will use a value of Zero volts for the field input regardless of the actual voltage applied. When
the jumper is installed Clearance monitoring (See Section 2.4) is automatically disabled for
that channel.
Example: To disable Yellow signal sensing on channel 9, a jumper wire must be
soldered in between the pair of holes labeled "9" in the area designated "YELLOW
DISABLE" on the program card.
4.4 OPTION SWITCH PROGRAMMING
The Signal Monitor provides switch options to modify the monitor operation. The Option
switches are labeled OPTIONS (SW3) and are located near the program card edge
connector.
4.4.1 RED FAIL TIMING SWITCH
Switch #1 of SW3 is labeled "RF 2010". When this switch is in the ON position, the Red Fail
fault time is set to the 2010 Standard value of 1350 ms. When this switch is in the OFF
position, the Red Fail fault time is set to the 210E series value of 850 ms. See Section 2.2.
4.4.2 RECURRENT PULSE (RP) DISABLE SWITCH (RP DISABLE)
Switch #2 of SW3 is labeled "RP DISABLE". When this switch is in the ON position, the
Recurrent Pulse detection mode is disabled. See Section 2.6.
4.4.3 WDT TIMING SWITCH
Switch #3 of SW3 is labeled "WD 1.0 SEC". When this switch is in the ON position, the
Watchdog fault time is set to 1.0 _
+0.1 seconds. When this switch is in the OFF position, the
Watchdog fault time is set to 1.5 _
+0.1 seconds. See Section 1.2.3.
4.4.4 GY ENABLE SWITCH
Switch #4 of SW3 is labeled "GY ENABLE". When this switch is in the ON position, all
channels will be monitored for a simultaneous active Green and Yellow input regardless of
the Red Enable input. See Section 2.3.1.
4.4.5 FYAC MODE-H SWITCH
Switch #5 of SW3 is labeled "FYAC MODE-H".
NYCDOT: This switch is non-functional. FYA Mode H is not provided in the 2010ECL-NYC.
4.4.6 LEDGUARD SWITCH
Switch #6 of SW3 is labeled "LEDguard". When this switch is in the ON position, the
LEDguard
®