7.4.
Remote monitoring function pinout
Event
Remote Monitoring
Output name
Common
LOCAL RM1
REL1_RT(1)
REL1_C(14)
FAULT RM2
REL2_RT(2)
REL2_C(15)
WARNING RM3 REL3_RT(3)
REL3_C(16)
RF (ON/OFF or 3DB
or both)
RM4 REL4_RT(4)
REL4_C(17)
ON
RM5
REL5_T(5)
REL5_C(6)
OFF RM6
REL5_R(5)
REL5_C(6)
VSWR RM7
REL6_RT(6)
REL6_C(7)
Numbers in parenthesis indicated the pin number on the DB25 connector.
A closed link indicates valid information when configuration is as in the following table.
Default jumper position:
Relay
Positions
Contacts
REL_1RT
JUMP2[1 ;2]
NO
REL2_RT
JUMP3[1 ;2]
NO
REL3_RT
JUMP5[1 ;2]
NO
REL4_RT
JUMP1[1 ;2]
NO
REL6_RT
JUMP4[1 ;2]
NO
Jumpers from 1 to 5 (JUMP1 to JUMP5): select the NO or NC contact of the relays.
L
When switching to local mode (relay 1), all other relays are disabled.