Helios FM 20/100 W, user manual– 12/2011
Page 13
Head Office : Parc d’activites Kennedy - 20, avenue Neil Armstrong – F-33700 Bordeaux-Merignac (France)
Tel +33 (0)5 57 928 928 – Fax +33 (0)5 57 928 929 –
www.ecreso.com – [email protected]
3.5.
AF inputs
Analog
(LINE1)
Connector "XLR"
type
Impedance
> 10 k
Ω
by default, adjustable to 600
Ω
by jumpers, unbalanced
Bandwidth Software
adjustable
Level
Software adjustable (-18/+18 dBu range)
AES
(LINE2)
Connector "XLR"
type
Impedance >
110
Ω
balanced
Bandwidth Software
adjustable
Level
Software adjustable (-20 to 0 dBFS range)
Sampling rate
Auto adjusted up to 192 kb/s
Bit
16, 24, 32
Multiplex (MPX/SCA)
Connector
"BNC" type
Impedance
> 5 k
Ω
unbalanced
Level
Software adjustable (-18/+18 dBu range)
3.6.
HF output
Connector N
type
Impedance 50
Ω
Monitoring (RF Monitor)
Level
10 dBm @ 20/100 W at main output
3.7.
Power supply
Voltage
90 VAC to 264 VAC
Frequency
50 Hz - 60 Hz
Max consumption
< 300 W @ nominal power