![ECR International Dunkirk DCB-100 Installation, Operation & Maintenance Manual Download Page 61](http://html1.mh-extra.com/html/ecr-international/dunkirk-dcb-100/dunkirk-dcb-100_installation-operation-and-maintenance-manual_2356127061.webp)
57
9 - START UP PROCEDURE
Parameters continued on next page
P13
Max. heating output
(0-100%)
73 100
80
P14
DHW max. output
(0-100%)
100
P15
Min. heating output
(0-100%)
00
P16
Maximum CH set-point (°C)
00
= 176°F (80°C)
01
= 113°F (45°C)
Selectable Range 20-80 = (20°C to 80°C) 68°F to 176°F
00
P17
Pump overrun time in heating mode
(01-240 minutes)
03
P18
Burner on delay with new call for heat
(0-10 minutes)
03
P20
Pump overrun time in DHW mode
(seconds)
30
P21
Anti-legionellosis function
00
= Disabled -
01
= Enabled
00
P22
Manufacturer information
(set “
22
” to access parameters
42
and above
)
00
P23
Maximum DHW set-point temperature
113°-140°F (45°-60°C), Default 49 = 120°F
49
P24
Manufacturer information
35
P26..P31
Manufacturer information
--
9.16 Description Of Parameters: Factory Settings
FACTORY SETTINGS
75 100,125,165 115,150,205
P01
DHW Fast Modulation
00
=Standard Modulation - on DHW call for heat 10 seconds stabilization time before
modulation
01
=Fast Modulation- on DHW call for heat 5 seconds stabilization time before modulation
01
P02
Gas used
00
= Gas A (Natural Gas)
01
= Gas E (LPG Gas)
00
P03
Hydraulic system
00
= instantaneous appliance
03
= instantaneous appliance with pre-heat function
04
= heating only appliance with DHW thermostat
05
= appliance with external storage indirect tank
08
= heating only appliance
13
= instantaneous appliance with pre-heat function for solar application
08
00
P09
Hydraulic Component Setting (1 = Brass)
Default 01
P10
Heating set-point setting OT / RT (Open Therm / Room Thermostat 120V~)
00
= with Remote Control (RC) connected, temperature request is RC set-point
01
= Temperature Request is highest set point between RC and PCB
02
= Temperature request is RU setpoint. The RT enable the gas boiler operates
00
P32..P41
Diagnostics
--
P44
Temperature unit setting
00
= °C
01
= °F
01
P67
OT/RT (Open Therm / Room Thermostat) selection.
2
=OT (open therm STD)
02
240013501 REV A [03/15/2022]
Summary of Contents for Dunkirk DCB-100
Page 2: ...DCC 205...
Page 4: ...DCB 165...
Page 79: ...75 A 2 MODEL 75 100 Heat Only APPENDIX A WIRING DIAGRAMS 240013501 REV A 03 15 2022...
Page 80: ...76 APPENDIX A WIRING DIAGRAMS A 2 MODEL 125 Heat Only 240013501 REV A 03 15 2022...
Page 81: ...77 APPENDIX A WIRING DIAGRAMS A 3 MODEL 165 Heat Only 240013501 REV A 03 15 2022...
Page 82: ...78 APPENDIX A WIRING DIAGRAMS A 1 MODEL 115 Combi 240013501 REV A 03 15 2022...
Page 83: ...79 APPENDIX A WIRING DIAGRAMS A 4 MODEL 150 Combi 240013501 REV A 03 15 2022...
Page 84: ...80 APPENDIX A WIRING DIAGRAMS A 5 MODEL 205 Combi 240013501 REV A 03 15 2022...
Page 85: ...81 NOTES 240013501 REV A 03 15 2022...
Page 86: ...82 NOTES 240013501 REV A 03 15 2022...
Page 121: ...33 PN 240011430 REV Q 03 15 2022 75 100 HEAT ONLY WIRING DIAGRAM MODEL 75 100 HEAT ONLY...
Page 122: ...34 PN 240011430 REV Q 03 15 2022 MODEL 125 HEAT ONLY 125 HEAT ONLY WIRING DIAGRAM...
Page 123: ...35 PN 240011430 REV Q 03 15 2022 MODEL 165 HEAT ONLY 165 HEAT ONLY WIRING DIAGRAM...
Page 124: ...36 PN 240011430 REV Q 03 15 2022 115 COMBI WIRING DIAGRAM MODEL 115 COMBI...
Page 125: ...37 PN 240011430 REV Q 03 15 2022 MODEL 150 COMBI 150 COMBI WIRING DIAGRAM...
Page 126: ...38 PN 240011430 REV Q 03 15 2022 MODEL 205 COMBI 205 COMBI WIRING DIAGRAM...
Page 132: ...44 PN 240011430 REV Q 03 15 2022 LOW WATER CUTOFF DETAIL LOW WATER CUTOFF NO NO YES...
Page 137: ...49 PN 240011430 REV Q 03 15 2022 3 FAULT SOLUTION SECTIONS...