28141 Rev A 10-27-06
22
Table A-13: Airflow Characteristics – Belt Drive
continued
CFM
External Static Pressure – Inches w.c.
Furnace Model
Motor
HP
Motor
FLA
∆
T
Blower
Blower
Pulley
Motor
Pulley
Turns
Out
0.20 0.25 0.30 0.40 0.50 0.60
0
1770 1725 1670 1560 1435 1288
2
1580 1525 1450 1305 1155 959
4 1380
1315
1245
1055
825
460
BCL(S)
80 – 145
BFL
80 – 145
3/4 HP
10.4
85°F
G10
5 x ¾
6 1205
1125
1020
775
365 71
0
2274 2177 2080 1847 1532 1099
2
2107 2017 1927 1712 1420 1019
4
1939 1857 1775 1576 1308 939
BCL
170 – 190
3/4 HP
13.0
85°F
G12
7 x ¾
6
1772 1697 1622 1441 1196 859
2
2601 2525 2449 2334 2164 2007
3
2549 2474 2399 2288 2120 1967
4
2497 2424 2350 2241 2077 1927
BCL
200 - 225
1 HP
14.0
85°F
G12
6 x ¾
5
2444 2373 2301 2194 2034 1887
Summary of Contents for BCL
Page 23: ...28141 Rev A 10 27 06 23 TABLE B 1 BECKETT AND RIELLO CHIMNEY VENTED WIRING DIAGRAM BCL S BFL ...
Page 24: ...28141 Rev A 10 27 06 24 TABLE B 2 BECKETT AND RIELLO DIRECT VENT WIRING DIAGRAM BCL S BFL ...
Page 29: ...29809 Rev A 10 19 2006 29 ...
Page 32: ...29809 Rev A 10 19 2006 32 ...
Page 36: ...29809 Rev A 10 19 2006 36 ...
Page 41: ...28141 Rev A 10 27 06 NOTES ...
Page 42: ...28141 Rev A 10 27 06 ...
Page 43: ...28141 Rev A 10 27 06 ...