28141 Rev A 10-27-06
17
Table A-8: Direct Drive Blower Set-Up
continued
Blower Set-Up
Cooling Capacity
0.20 in. w.c.
0.50 in. w.c.
Furnace Model
Blower
Speed Motor Speed Motor
Tons Motor
CFM
Range
BFL-80, (U)
G10 DD
DD10-10A
Med-Low
1/2 HP
Med-Low
1/2 HP
3 – 4
1/2 HP
1000 – 1600
BFL-80, (U), (T)
DD12-11T
DCT12-11
Low
1 HP
Low
1 HP
3 - 5
1 HP
1300 - 2000
BFL-90, (U)
G10 DD
DD10-10A
Med-High 1/2
HP Med-High 1/2 HP
3 – 4
1/2 HP
1000 – 1600
BFL-90, (U), (T)
DD12-11T
DCT12-11
Low
1 HP
Low
1 HP
3 - 5
1 HP
1300 - 2000
BFL-100, (U)
G10 DD
DD10-10A
Med-High 1/2
HP Med-High 1/2 HP
3 – 4
1/2 HP
1000 – 1600
BFL-100, (U), (T)
DD12-11T
DCT12-11
Low
1 HP
Low
1 HP
3 - 5
1 HP
1300 - 2000
BFL-120, (U)
G10 DD
DD10-10A
High
1/2 HP
High
1/2 HP
3 – 4
1/2 HP
1000 – 1600
BFL-120, (U), (T)
DD12-11T
DCT12-11
Medium
1 HP
Medium
1 HP
3 - 5
1 HP
1300 - 2000
BFL-130
G10 DD
DD10-10A
High
1/2 HP
High
1/2 HP
3 – 4
1/2 HP
1000 – 1600
BFL-130, (T)
DD12-11T
DCT12-11
Medium
1 HP
Medium
1 HP
3 - 5
1 HP
1300 - 2000
BFL-145
G10 DD
DD10-10A
High
1/2 HP
High
1/2 HP
3 – 4
1/2 HP
1000 – 1600
BFL-145, (T)
DD12-11T
DCT12-11
High
1 HP
High
1 HP
3 - 5
1 HP
1300 - 2000
NOTE - Model Suffix Denotations: S: BCL with “S” series Heat Exchanger, T: High Air Flow Model (5 Ton), U: Sidewall Vented Model
Summary of Contents for BCL
Page 23: ...28141 Rev A 10 27 06 23 TABLE B 1 BECKETT AND RIELLO CHIMNEY VENTED WIRING DIAGRAM BCL S BFL ...
Page 24: ...28141 Rev A 10 27 06 24 TABLE B 2 BECKETT AND RIELLO DIRECT VENT WIRING DIAGRAM BCL S BFL ...
Page 29: ...29809 Rev A 10 19 2006 29 ...
Page 32: ...29809 Rev A 10 19 2006 32 ...
Page 36: ...29809 Rev A 10 19 2006 36 ...
Page 41: ...28141 Rev A 10 27 06 NOTES ...
Page 42: ...28141 Rev A 10 27 06 ...
Page 43: ...28141 Rev A 10 27 06 ...