ECOWATER
S Y S T E M S
English
38
4.10 CONDUCTIVITY METER (OPTIONAL)
In order to have a permanent monitoring of the quality of the water produced, a conductivity meter can be
placed in the electrical cabinet.
The conductivity meter is provided with analogue output and will be displayed on the LCD display. The
meter has a built-in temperature compensation. The measurements are accurate and can be calibrated by
EcoWater with the PC. One LED on the meter indicates whether the measured value is in the measurement
range and if an alarm occurs (0 - 200 μS).
SPECIFICATIONS
Range
0 to 200 µS/cm
Resolution
1 µS/cm
Accuracy (@25°C)
+/- 1% at full scale
Set point
Adjustable from 0 to 200 µS/cm
Alarm
This will be displayed on the LCD display of the
processor
Temperature compensation
Automatically from 5 to 50°C
Attention
: All conductivity meters are calibrated in our workplace.
4.10.1 SET POINT
To set the alarm point (threshold), press the ◄ or ▼ button.
The display shows the currently set value of the conductivity
and the delay of the alarm (see above).
Press the white button and keep it pressed.
Now “Param” above the ► button appears now press this
button while the white button is pressed.
Now it says “Prog” Now let the white button loose.
Use ◄ or ► to select the parameter to adjust. Use ▲ or ▼ to
increase or decrease your value.
Once the value is adjusted, press again on the white button and
then pressing the ► button until “Param” is displayed above
this button again.
Release the white button back loose and the values are
adjusted.
Now press ◄ or ▼ to get the situation screen of the osmosis
installation.
Summary of Contents for ROHD 4000
Page 16: ...ROHD SB ROHD 4000 Rev 19 09 2017 MANUEL D UTILISATION EcoWater Systems Europe www ecowater be ...
Page 31: ...ROHD SB ROHD 4000 Rev 19 09 2017 USER GUIDE EcoWater Systems Europe www ecowater be ...
Page 46: ...ECOWATER S Y S T E M S 46 ELEKTRISCH SCHEMA SCHEME ÉLECTRIQUE ELECTRICAL SCHEME ROHD SB ...
Page 47: ...ECOWATER S Y S T E M S 47 ELEKTRISCH SCHEMA SCHEME ÉLECTRIQUE ELECTRICAL SCHEME ROHD SB ...
Page 48: ...ECOWATER S Y S T E M S 48 ELEKTRISCH SCHEMA SCHEME ÉLECTRIQUE ELECTRICAL SCHEME ROHD SB ...
Page 49: ...ECOWATER S Y S T E M S 49 ELEKTRISCH SCHEMA SCHEME ÉLECTRIQUE ELECTRICAL SCHEME ROHD SB ...
Page 50: ...ECOWATER S Y S T E M S 50 ELEKTRISCH SCHEMA SCHEME ÉLECTRIQUE ELECTRICAL SCHEME ROHD 4000 ...
Page 51: ...ECOWATER S Y S T E M S 51 ELEKTRISCH SCHEMA SCHEME ÉLECTRIQUE ELECTRICAL SCHEME ROHD 4000 ...
Page 52: ...ECOWATER S Y S T E M S 52 ELEKTRISCH SCHEMA SCHEME ÉLECTRIQUE ELECTRICAL SCHEME ROHD 4000 ...
Page 53: ...ECOWATER S Y S T E M S 53 ELEKTRISCH SCHEMA SCHEME ÉLECTRIQUE ELECTRICAL SCHEME ROHD 4000 ...
Page 55: ...ECOWATER S Y S T E M S 55 Your Water Perfected ...