![Ecotherm EDRE Operating And Maintenance Instructions Manual Download Page 11](http://html1.mh-extra.com/html/ecotherm/edre/edre_operating-and-maintenance-instructions-manual_2355617011.webp)
T
S
S
D2
S
D1
F
B
P
11
ECOTHERM
Heat transfer solutions
®
Operating Instructions High Capacity Water Heaters Models EHRE/EHPE & EDRE - ELC 11
3. Installation and assembly
installation and assembly
storage
capacity
B
D1
D2
f
min.
s
min.
t
P
min.
tank
weight
empty
liter
mm mm mm mm mm mm
mm
kg
300
500
500
660 1000 600 1460 1860 x 1060
60
540
500
650
810 1000 600 1610 2010 x 1210
80
750
500
750
910 1000 600 1710 2110 x 1310
110
1000
500
890 1110 1200 600 1910 2310 x 1510
130
1250
500 1000 1220 1200 600 2020 2420 x 1620
197
1500
500 1100 1320 1200 600 2120 2520 x 1720
228
2000
500 1250 1470 1400 600 2270 2670 x 1870
335
2500
500 1350 1570 1400 600 2370 2770 x 1970
417
3000
500 1350 1570 1400 600 2370 2770 x 1970
470
4000
500 1500 1720 1600 600 2520 2920 x 2120
681
5000
500 1700 1920 1600 600 2720 3120 x 2320
940
3.1 Space requirement
the eH high capacity water heater should be installed in a
frost-protected room. For tank installation the following minimum
clearances shown in the following drawings should be provided.
3.1a Space requirement for additional tanks
for eCotHerM water heater models with more
than one storage tank, the space requirement
for each additional tank is added to the space
requirement of the main tank (refer to section 3.1).
storage
capacity
D1
D2
s
mini-
mum
additional
plinth P
2
minimum
liter
mm
mm
mm
mm
300
500
660
600
1530 x 1060
540
650
810
600
1710 x 1210
750
750
910
600
1810 x 1310
1000
890
1110
600
2010 x 1510
1250
1000
1220
600
2120 x 1620
1500
1100
1320
600
2220 x 1720
2000
1250
1470
600
2370 x 1870
2500
1350
1570
600
2470 x 1970
3000
1350
1570
600
2470 x 1970
4000
1500
1720
600
2620 x 2120
5000
1700
1920
600
2820 x 2320
P = Plinth or Platform
(optional, scope of
building)
Fig 3: Space requirements for type
EH high capacity water heater
Table 1: Clearance distances for the high capacity water heater
P
2
= additional plinth or
platform
(optional, scope of building)
Fig 4: Space requirement per additional tank
Table 1a: Space requirement per additional storage tank
S
S
D2
S
D1
P
2
S
Additional tank Main tank