TP-M11
10
cooling, the normal heating or cooling
speed will over-ride the continuous fan
setting. Once the thermostat is satisfied,
continuous fan speed will resume.
PRODUCT DESCRIPTION
Ecologix air handlers are certified by:
Entela Inc.
81 Kelfield St., Unit 7
Toronto, Ontario
M9W 5A3
Ph: 416-241-8427
Fx: 416-241-0682
Ecologix air handlers are in conformity
with the following standards:
CAN CSA-22.2 No. 236M95
UL 1995 2
nd
Ed.
As shown in certification report number:
0301154695, File number 8502, dated:
01/27/03
Cabinet
All cabinets have a tough, durable low
maintenance pre-painted finish.
Cabinet dimensions are designed to
provide maximum installation flexibility.
Refer to installation requirements for
more details.
Heating Coils
All heating coils are potable water grade
copper suitable for use in plumbing
systems. No lead solder is used in any
component construction. All coils and
internal piping conform to ASTM B68 or
ASTM B88 standards.
High-density aluminum fins provide
maximum heat transfer for small coil
surface.
Fan and Motor
All fans are wide body dynamically
balanced for extra quiet operation.
Multi-directional sleeve bearing motors
allow mounting in any direction for
maximum installation flexibility.
Circulating Pump
The circulating pump is matched for
maximum performance. Air handlers
come with internally mounted pumps for
ease of installation. Air handlers can be
special ordered with external, field
installed pumps, when it is desirable to
locate the circulator below the air
handler, such as in attic installations.
Check Valve
Check valves serve two purposes:
•
protect against back-flow of water to
avoid short circuiting around the
water heater during domestic water
use.
•
protect against thermal siphoning.
Thermal siphoning is flow of water
through the space heating circuit while
the circulating pump is not operating due
to hot water rising by natural convection.
During summer months this will cause
overheating, interfere with air
conditioning and waste energy.