TP-M11
8
Unit Specifications: Thermal-Duct
TM
air handlers
MODEL
TDHV-
12
TDHV-
18
TDHV-
24
TDHV-
30
TDHV-
36
TDHV-
42
TDHV-
48
TDHV-
60
Number of 3”
outlets
1
8
12
15
18
22
26
30
36
Cooling Capacity
(Tons)
1.0
1.5
2.0
2.5
3.0
3.5
4.0
5.0
*Heating Capacity
(MBH) 130F water
15
21
35
41
46
49
52
57
*Heating Capacity
(MBH) 140F water
18
25
41
48
54
57
61
67
*Heating Capacity
(MBH) 160F water
24
33
53
62
69
74
78
86
*Heating Capacity
(MBH) 180F water
30
40
65
76
85
91
96
105
(USGPM) Heating
2.3
2.3
4.5
4.5
4.5
4.5
4.5
4.5
Nominal Airflow
(CFM)
2
360
540
720
900
1080
1260
1440
1800
Max. Design ESP
Heat Only (“WC)
1.0
0.8
0.9
0.7
0.8
0.6
1.0
0.5
Max. Design ESP
Heat/Cool (”WC)
3
0.9
0.7
0.8
0.4
0.5
0.3
--
--
Blower Motor Full
Load (Amps)
4
4
5
5
7
7
10
10
Circulator Full
Load (Amps)
0.6
0.6
0.8
0.8
0.8
0.8
0.8
0.8
1. Minimum Required. Refer to Design and Installation Instructions for options.
2.
All air flows at high speed.
3.
Using Ecologix cased slab cooling coils. Above 3.5 tons, use an A-coil.