53
4.24.
The air input pipe should not be drained with the risk of affecting the correct operation of the stove. For this
reason, and in order to facilitate fresh air input, it is necessary to set up a ventilation grid
AT NOT LESS
than
50cm both horizontally and vertically from gas output,
see point
4.19.
Direct air currents shall also be avoided as they might prevent a correct operation of the stove and as a
consequence, heat performance.
Ventilation of the room must meet the minimum flow required according to specific regulations and the
maximum intake air flow of the machine.
Extraction fans can cause problems when operating in the same room or in the same space as the appliance.
4.25.
In any case the design of the chimney termination will impede the free diffusion in the atmosphere of
combustion products. A metallic mesh with a gap of 3x3 cm can be placed to avoid the entry of birds or
unwanted objects.
4.26.
If a testing module is installed to collect combustion gas readings and samples, it must be equipped with
hermetic and self-locking sealing.
EXAMPLES OF FLUE INSTALLATIONS.
Although we cannot keep track of or describe every single installation, option, or the local installation
regulations corresponding to your area, Ecoforest guarantees that the installations suggested below will enable
your stove to function properly, and to conform to minimum personal and material safety measures.
If you are installing your stove in a building, in addition to respect local regulations on gas flues, you should
consult with the residents’ association to avoid future problems.
Please read the entire manual carefully, especially the chapter on installation to ensure your stove
operates properly and at full power.
If the total pipe length exceeds 8m, it is recommended to increase one measure, being able to make the
whole assembly in the same diameter from the connection of the stove or increase section from 4 m.
4.27.
The installation shown below is the one recommended by Ecoforest to get the best machine performance.
The pipe section will run at least 2 meters vertically through the interior of the house.
Drawing 13
Other installations are possible as well (please check with your authorised dealer.) Other possibilities are
added herebelow:
4.28.
Outdoor pipe. Take into account the installation of double wall piping.
Windbreak.
Stainless steel hose clamp.
T of 90° with outlet.
Insulator.
Wooden ground.
Non flammable floor protection.
Elbow of 90°.
*Distance equal to or over 2 metres.
MAXIMUM
1 metre.