![ECOFOREST BOLONIA VPA 00-00 Installation And Maintenance Manual Download Page 44](http://html1.mh-extra.com/html/ecoforest/bolonia-vpa-00-00/bolonia-vpa-00-00_installation-and-maintenance-manual_2354362044.webp)
43
1.12.
STOVES DATA.
MARSELLA
RS
PARÍS
RP
BOLONIA
VPA 00-00
TOKIO
CO 00-00
CONNECTIONS
Gas output Ø
mm
80
80
80
80
Air imput airtight pipe Ø
mm
30
30
- -
- -
Convection air duct Ø
mm
- -
- -
1x100
- -
AIR ADMISSION
Maximum air flow admission*
m
3
/h
36,2
41,0
43,2
46,2
Minimum draught recommended
mBar
0,10 – 0,12
0,10 – 0,12
0,10 – 0,12
0,10 – 0,20
Pa
10 - 12
10 - 12
10 - 12
10 - 20
GENERAL FEATURES
Weight
Kg
115
110
143
146
Operate with wood pellets
A1
Si
Si
Si
Si
Hopper capacity **
Kg
15
20
20
30
Safety thermostat tared
°C
125
125
93
93
Noise at level 9, 3 meters in length and 1.5 meters in height.
dB
42,5
42,5
44,1
48,1
NOMINAL HEAT OUTPUT
Fuel drop level
1 - 9
9
9
9
9
Nominal heat output
kW
9,9
10,0
10,0
12,0
Efficiency
%
90,0
87,0
90,0
90,0
Consumption
kg/h
2,2
2,3
2,2
2,7
Approximate autonomy
h
9
9
9
11
CO content (with O
2
levels of 13%)
%
0,02
0,01
0,02
0,02
mg/Nm
3
240
101
241
239
NOx.
mg/Nm
3
188
185
196
190
OGC.
mg/Nm
3
6
12
17
18
PM.
mg/Nm
3
19
18
20
19
Exhaust mass flow
g/s
8
9
10
10
Tª media de los humos
°C
170
173
173
180
Auxiliary power consumption
W
180
80
90
255
Flow and average temperature of conducted air
m
3
/h
- -
- -
- -
°C
- -
- -
- -
REDUCED HEAT OUTPUT
Fuel drop level
1 - 9
1
1
1
1
Reduced heat output
kW
4,5
3,2
4,9
5,0
Efficiency
%
92,0
84,0
92,9
91,0
Consumption
kg/h
1,0
0,8
1,0
1,1
Approximate autonomy
h
15
26
19
27
CO content (with O
2
levels of 13%)
%
0,02
0,02
0,02
0,02
mg/Nm
3
285
288
297
243
NOx.
mg/Nm
3
196
189
194
195
OGC.
mg/Nm
3
10
29
19
19
PM.
mg/Nm
3
20
19
20
20
Exhaust mass flow
g/s
5
7
5
8
Tª media de los humos
°C
70
100
95
110
Auxiliary power consumption
W
88
44
30
130
Space heating seasonal energy efficiency (
ŋ
s).
%
85,2
83,7
86,8
84,6
* Estimation according to mass flow and gas temperature in nominal power
**Fuel estimate
ρ
ap
≈630 kg/m
3
UNE EN 14785