background image

 
© Eco Heat Equipment

 –

 Oct 2016

 

                                                                     1 of 2 

 

ES701 Passive Infrared (PIR) IP65 Motion Sensor User 

Manual 

 

 

 

General 

The ES701 PIR IP 65 motion sensor is ideal for outdoor or high humidity applications, 
such  as  outdoor  lights  and  bathrooms  loads.  The  sensor  has  an  extruding  screw 

that can easily be installed directly onto a light fixture.  

If, after reviewing this guide, you require additional information or assistance 

please contact Eco Heat Equipment at [email protected], +27 (0)861 999 887, 

or www.ecosensor.co.za.  

Technical Specifications 

§

 

Voltage: 220 – 240V/AC 

§

 

Frequency:  50/60Hz 

§

 

Load:  Incandescent max: 450W 

            Fluorescent max: 275W 

            LED max: 150W 

§

 

Detection Angle: 360 ° 

§

 

Detection Range: 1.4 m- 8m radius (dependent on mounting height)  

§

 

Light level: 10 – 50 LUX and 24H 

§

 

Time setting: 10 seconds – 60 minutes 

§

 

Dimming Level: 0%, 10%, 20% and 30%, Dimming Function Off 

§

 

Installation height: 2.5 - 7m max 

§

 

Working temperature: -10°C to 35°C 

§

 

IP Rating: IP65 

§

 

Dimensions: Length: 129.6mm (149mm with connector) 

                     Width: 36.4mm 
                     Height: 28mm  

                     Connector inside diameter: 17.1mm 

                     Connector outside diameter: 20.4mm  

 

 
Safety 

Any  incorrect  use  or  installation  procedure  not  recommended  by  the 

manufacturer may cause fire, electrical shock or injury to persons. 

 

Box Contents  

Your box should contain the following items: 

§

 

Sensor 

§

 

Silicone Washer 

§

 

M20 Nut 

§

 

2 x spacers 

 

 

WARNING:  

Controlling a load in excess of the specified ratings will damage the unit and lights 

and could pose risk of fire and electric shock. 
  

Do not install this unit to control a power socket. 

  

Installation Instructions 

WARNING:  ALL  WIRING  MUST  BE  DONE  IN  ACCORDANCE  WITH  NATIONAL  AND 
LOCAL ELECTRICAL CODES AND STANDARDS. 

 

Note: motion sensors respond to rapid changes in temperature so care should be 

taken  not  to  mount  the  device  near  a  climate  control  source  (i.e.  heaters  or  air 

conditioners). Hot or cold draughts will seem like body motion to the sensor and will 
trigger the device. Recommended distance from climate control devices is 2m. 

 

1. Turn power off at circuit breaker or fuse 

2. Connect wires as per diagram 
3. Sensor can be secured onto light fitting 

4. Restore power at circuit breaker or fuse 

Sensor calibration: 

Note:

  Allow  up  to  1  minute  for  the  motion  sensor  to  recalibrate  after  it  has  been 

connected for the very first time. This is only necessary during installation or when 

the mains supply is disconnected.  

 

 

Installation wire diagram – NO DIMMING DIRIVER 

 

 

 
 

 

 

 

 
 

 

 

 
 

 

 

 

Installation wire diagram – DIMMING DIRIVER 

 
 

 

 

 

 
 

 

 

 

 
 

 

 

 
 

 

 

Operation and Field of View 

The motion sensor detects motion within its coverage area and controls the 
associated lighting connected to the sensor. The passive infra red (PIR) sensor is 

sensitive to the heat emitted by the human body. In order to trigger the sensor the 

source of heat must move from one zone of detection to another. The device is 

most effective in sensing motion across its field of view and less effective sensing 

motion towards or away from its field of view**. 
 

Sensor detection range from side: large motion* across detection zone 

 

 

 

*Detection range for large motion at 2.8m height: 14m (diameter). 

**Detection Range will decrease with approximately 35% with movement towards 

or away from the sensor  

 

Sensor detection range: large motion* towards/away sensor 

 

 

 

 
 

 

 

 

 
 

 

 

 

 

 

 

Motion Sensor Settings and Adjustments 

The motion sensor is a Passive Infra Red (PIR) type electronic occupancy detector, 

which in turn switches the lights when connected to the motion sensor. There are 

five adjustments (three if the dimming function is not used) that can be made to 
influence the operation of the motion sensor:  

1.

 

RANGE/SENSITIVITY: motion detection range 

2.

 

STAND-BY TIME: time delay after motion until shut off/dimming 

3.

 

LUX/LIGHT: level of ambient light sensitivity 

4.

 

DIMMING LEVEL: level of dimming required* 

5.

 

DIMMING TIME: time delay after motion until shut off * 

 

* Only applicable if grey and violet wires are connected to dimming driver 

 

 

 

The five adjustments settings are as follows: 

Detection/Sensitivity range:              20%, 50%, 75%, 100%  
Stand-by time setting range:             10 sec, 1 min, 5min, 15min, 30min, 60 min  

Lux (light) sensitivity: 

            24H,10 LUX, 30LUX 

Dimming level: *                                  0%, 10%, 20%, 30% 

Dimming time: *                                  24H, 1 min, 30min, 60min, 24H 

 
* Only applicable if grey and violet wires are connected to dimming driver 

 
 
Motion Sensor Adjustments 

The motion sensor’s settings is adjusted using the ES-REMD remote control.

 

 
 