background image

10 in.

min.

6 in.
min.

IN

OUT

House W
Supply

Sump

Pointed
Straight

Down

6

Planning the Installation (continued)

FIG. 4

FIG. 6

FIG. 5

10 in.

min.

B

D

E

Remove 2

screws and

turn faceplate

around, if

necessary

ALWAYS INSTALL THE FILTER UPRIGHT

To operate properly, the Automatic Sediment Filter

must be installed with the sump pointed straight down.

When possible, install the filter on a horizontal section

of the household’s main incoming water pipe.  If the

available incoming main house water pipe runs verti-

cally where you want to install the filter, buy 90° pipe

elbows and plumb a detour, as shown in Figure 4.

Allow enough space under the filter (6” minimum) to

remove the sump (to clean or replace the filter screen).

Allow enough space above the filter to remove the top

cover (to change batteries, etc.), as shown in Figure 4.

REVERSING THE FACEPLATE / DISPLAY

The Automatic Sediment Filter must be installed with

the water flowing into the side of the filter marked 

IN

.

Remove the unit’s top cover and observe the IN and

OUT markings.  Depending on the direction of water

flow and the viewing angle, the faceplate may need to

be reversed (turned around to face the opposite direc-

tion) so that it does not end up against a wall or other

obstruction.  This can be done either before or after

the filter is installed on the plumbing:

1

. Remove the top cover from the ASF by sliding it

upward.

2

. With a phillips screwdriver, remove the 2 screws

holding the faceplate assembly to the filter head

(See Figure 5).

3

. Lift the faceplate assembly up and turn it around

180°, taking care not to pull on the wires between

the electronic control board and the valve solenoid.

4

. Lower the faceplate assembly into place on the

opposite side of the head and reinstall the 2 screws.

5

. Slide the top cover back onto the ASF and push it

down to snap into place.

MOUNTING BRACKET

A metal bracket is included with the Automatic

Sediment Filter to support the assembled filter and

plumbing when necessary.  It may be mounted to a

wall or wall framing member with 2 screws (included),

as shown in Figure 6.

Mounting

Bracket

House

Water

Supply

Pipe

IN

OUT

6 in.

min.

Sump

Pointed

Straight

Down

Summary of Contents for EP-ASF15

Page 1: ...Friday 7 AM 6 PM CST or visit www ecopure com U S A www ecopure ca Canada When you call please be prepared to provide the model date code and serial number of your product found on the rating decal lo...

Page 2: ...disposed of accord ing to Waste Electrical and Electronic Equipment WEEE requirements This directive or similar laws are in place nationally and can vary from region to region Please refer to your sta...

Page 3: ...urther that the Automatic Sediment Filter is not damaged as the result of any unusu al force of nature such as but not limited to flood hurricane tornado or earthquake Warrantor is excused if failure...

Page 4: ...1 8 in 5 1 4 in 9V Battery Hose Clamp INSPECT SHIPMENT The Automatic Sediment Filter is shipped complete in one carton Remove all items from the shipping carton and check against the packing list bel...

Page 5: ...ediment Filter is designed to be plumbed into a home s incoming water supply pipe where it will capture particles of sediment from the water and periodically flush them down the drain The unit has an...

Page 6: ...s top cover and observe the IN and OUT markings Depending on the direction of water flow and the viewing angle the faceplate may need to be reversed turned around to face the opposite direc tion so t...

Page 7: ...8 CMR shall be adhered to A licensed plumber shall be used for this installation AIR GAP REQUIREMENTS A drain is needed for sediment flush discharge water A floor drain close to the Automatic Sediment...

Page 8: ...llowing before turning the water supply back on 1 Measure cut to needed length and connect the 3 8 in drain line provided to the Automatic Sediment Filter s valve drain fitting See Figure 8 on Page 7...

Page 9: ...Parts List page for ordering information IMPORTANT Do not use any AC adaptor other than the EcoPure P N 7302835 with this Automatic Sediment Filter To install the optional AC adaptor 1 Remove the top...

Page 10: ...in will start and stop several times 4 Once the sediment flush has been completed the 2 digit display will change to show the number of days until the next automatic flush or if the automatic flush fe...

Page 11: ...increases the number of days by 1 When the number passes 30 it returns to zero indicated by and counts up from 1 again 3 Setting the number of days to zero turns off the automatic flush feature 4 When...

Page 12: ...e water you saved in Step 1 wash the filter screen assembly If necessary gently scrub the filter mesh with a soft brush to remove material from the pores 7 The drain straw may have come out of the ASF...

Page 13: ...off the water supply as directed in Step 2 run a bucketful or sinkful of water to use for cleaning 2 Shut off the main house water supply valve upstream from the Automatic Sediment Filter 3 Open a col...

Page 14: ...Head Assembly 17 7300312 O Ring Sump 18 7298395 Sump 19 7300304 Drain Straw Key No Part No Description 20 7298808 Filter Screen Assembly 60 Micron includes Key No 21 7298816 Filter Screen Assembly 100...

Reviews: