background image

2

Table of Contents

Before You Start

=

Read this entire manual before installing and using your Automatic Sediment Filter.  Then, obtain all the materials

and tools you will need to make the installation.  Follow all steps exactly and in order to correctly install.

=

The Automatic Sediment Filter must only be installed vertically, with the head up and the sump down.  It will not

operate properly if installed horizontally or at an angle.

=

Check local plumbing, electrical and sanitation codes.  You must follow their guides as you install the system.

=

Use only lead-free solder and flux for all sweat-solder connections, as required by federal codes.

=

Maximum operating pressure: 100 psi.

=

Maximum operating temperature: 120 °F.

=

Avoid installing in direct sunlight.  Excessive sun heat may cause distortion or other damage to non-metallic parts.

=

For cold water use only.  Do not install on a hot water line.

=

Do not use this system to treat water that is microbiologically unsafe or of unknown quality without adequate dis-

infection before or after the system.

=

Keep solvents and sprays away from the clear sump housing material.  Surface cracking and failure can result.

European Directive 2002/96/EC requires all electrical and electronic equipment to be disposed of accord-

ing to Waste Electrical and Electronic Equipment (WEEE) requirements.  This directive or similar laws

are in place nationally and can vary from region to region.  Please refer to your state and local laws for

proper disposal of this equipment.

In the state of Massachusetts: The Commonwealth of Massachusetts plumbing code 248-CMR shall

be adhered to.  A licensed plumber shall be used for this installation.

Before You Start  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Warranty  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Unpacking  

§

Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

How the Automatic Sediment Filter Works  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Specifications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Planning the Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6

Installation Location  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Always Install the Filter Upright  

§

Reversing the Faceplate  

§

Mounting Bracket . . . . . . . . . . . . . . . . . . . . . . 6

Installation Requirements  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Air Gap Requirements  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Valve Drain Requirements  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Grounding Information  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-9

Attach the Adaptors and Clips to the Filter  

§

Connect the Water Supply Lines . . . . . . . . . . . . . . . . . . . . . . . . 8

Install the Drain Hose  

§

Check For Leaks  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Install Battery  

§

Optional AC Adaptor  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Programming the Electronic Controller  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-11

Power Up  

§

Manually Start a Sediment Flush  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Normal Operation  

§

LCD Backlight  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Setting Number of Days Between Automatic Sediment Flushes  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Time of Day When Flush Occurs  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Low Battery Indication  

§

Battery Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Routine Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Cleaning the Filter Screen  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Troubleshooting Guide  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Disassembly of Solenoid  

§

Disassembly of Valve  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Repair Parts  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Questions? Call Toll Free 1-800-693-1138

, Monday - Friday, 7 am - 6 pm CST.

Summary of Contents for EP-ASF15

Page 1: ...Friday 7 AM 6 PM CST or visit www ecopure com U S A www ecopure ca Canada When you call please be prepared to provide the model date code and serial number of your product found on the rating decal lo...

Page 2: ...disposed of accord ing to Waste Electrical and Electronic Equipment WEEE requirements This directive or similar laws are in place nationally and can vary from region to region Please refer to your sta...

Page 3: ...urther that the Automatic Sediment Filter is not damaged as the result of any unusu al force of nature such as but not limited to flood hurricane tornado or earthquake Warrantor is excused if failure...

Page 4: ...1 8 in 5 1 4 in 9V Battery Hose Clamp INSPECT SHIPMENT The Automatic Sediment Filter is shipped complete in one carton Remove all items from the shipping carton and check against the packing list bel...

Page 5: ...ediment Filter is designed to be plumbed into a home s incoming water supply pipe where it will capture particles of sediment from the water and periodically flush them down the drain The unit has an...

Page 6: ...s top cover and observe the IN and OUT markings Depending on the direction of water flow and the viewing angle the faceplate may need to be reversed turned around to face the opposite direc tion so t...

Page 7: ...8 CMR shall be adhered to A licensed plumber shall be used for this installation AIR GAP REQUIREMENTS A drain is needed for sediment flush discharge water A floor drain close to the Automatic Sediment...

Page 8: ...llowing before turning the water supply back on 1 Measure cut to needed length and connect the 3 8 in drain line provided to the Automatic Sediment Filter s valve drain fitting See Figure 8 on Page 7...

Page 9: ...Parts List page for ordering information IMPORTANT Do not use any AC adaptor other than the EcoPure P N 7302835 with this Automatic Sediment Filter To install the optional AC adaptor 1 Remove the top...

Page 10: ...in will start and stop several times 4 Once the sediment flush has been completed the 2 digit display will change to show the number of days until the next automatic flush or if the automatic flush fe...

Page 11: ...increases the number of days by 1 When the number passes 30 it returns to zero indicated by and counts up from 1 again 3 Setting the number of days to zero turns off the automatic flush feature 4 When...

Page 12: ...e water you saved in Step 1 wash the filter screen assembly If necessary gently scrub the filter mesh with a soft brush to remove material from the pores 7 The drain straw may have come out of the ASF...

Page 13: ...off the water supply as directed in Step 2 run a bucketful or sinkful of water to use for cleaning 2 Shut off the main house water supply valve upstream from the Automatic Sediment Filter 3 Open a col...

Page 14: ...Head Assembly 17 7300312 O Ring Sump 18 7298395 Sump 19 7300304 Drain Straw Key No Part No Description 20 7298808 Filter Screen Assembly 60 Micron includes Key No 21 7298816 Filter Screen Assembly 100...