background image

11

Electronic Controller (continued)

LED blinking

red

every 8

sec. indicates

battery is low

“E E” in the

display indi-

cates battery

is low

FIG. 17

Two dashes

(not moving)

in the display

indicate auto-

matic flush is

turned off

FIG. 16

3

. Take a new 9-volt battery and snap the battery con-

nector onto both terminals.

4

. Place the connected battery into the clip provided

for it directly above the IN port (See Figure 12 on

Page 9).

5

. Slide the top cover back onto the ASF and push it

down to snap into place.

No reprogramming of the controller is necessary after

battery replacement or a power outage.

The ASF controller is shipped with a default value of 7

days between automatic sediment flushes.  To change

the number of days (between 1 and 30) or to turn this

feature off:

1

. Press the PROGRAM button and hold it for at least

2 seconds.  When the LED turns on steadily with an

amber color, quickly release the PROGRAM button.

2

. While the amber LED is on (it turns off after 10 sec-

onds of button inactivity), repeatedly press the PRO-

GRAM button until the desired number of days

shows in the display.  Each press increases the

number of days by 1.  When the number passes 30,

it returns to zero, indicated by “- -”, and counts up

from 1 again.

3

. Setting the number of days to “- -” (zero) turns off

the automatic flush feature.

4

. When the desired number of days shows in the dis-

play, wait 10 seconds (press no more buttons) for

the amber LED to go off.  The new number of days

is programmed.  This new setting will remain after

battery change or power loss.

TIME OF DAY WHEN FLUSH OCCURS

The time of day when the automatic sediment flush will

occur is the same time of day as when the most recent

of the following was done:

=

The filter was powered up (battery installed or

replaced, optional AC adaptor plugged in).

=

The number of days was set

=

A manual flush was initiated

If a different time of day is desired for automatic flush,

simply initiate a manual flush (as described on the pre-

vious page) at the desired time of day.

LOW BATTERY INDICATION

If the LED is blinking red every 8 seconds (and the 2-

digit display shows “E E“), then the battery needs to be

replaced.

BATTERY REPLACEMENT

1

. Remove the top cover from the ASF by sliding it

upward (See Figure 12 on Page 9).

2

. Locate the old battery and unsnap it from the bat-

tery connector.  Dispose of (recycle) old battery

properly.

SETTING THE NUMBER OF DAYS BE TWEEN

AUTOMATIC SEDIMENT FLUSHES

Summary of Contents for EP-ASF15

Page 1: ...Friday 7 AM 6 PM CST or visit www ecopure com U S A www ecopure ca Canada When you call please be prepared to provide the model date code and serial number of your product found on the rating decal lo...

Page 2: ...disposed of accord ing to Waste Electrical and Electronic Equipment WEEE requirements This directive or similar laws are in place nationally and can vary from region to region Please refer to your sta...

Page 3: ...urther that the Automatic Sediment Filter is not damaged as the result of any unusu al force of nature such as but not limited to flood hurricane tornado or earthquake Warrantor is excused if failure...

Page 4: ...1 8 in 5 1 4 in 9V Battery Hose Clamp INSPECT SHIPMENT The Automatic Sediment Filter is shipped complete in one carton Remove all items from the shipping carton and check against the packing list bel...

Page 5: ...ediment Filter is designed to be plumbed into a home s incoming water supply pipe where it will capture particles of sediment from the water and periodically flush them down the drain The unit has an...

Page 6: ...s top cover and observe the IN and OUT markings Depending on the direction of water flow and the viewing angle the faceplate may need to be reversed turned around to face the opposite direc tion so t...

Page 7: ...8 CMR shall be adhered to A licensed plumber shall be used for this installation AIR GAP REQUIREMENTS A drain is needed for sediment flush discharge water A floor drain close to the Automatic Sediment...

Page 8: ...llowing before turning the water supply back on 1 Measure cut to needed length and connect the 3 8 in drain line provided to the Automatic Sediment Filter s valve drain fitting See Figure 8 on Page 7...

Page 9: ...Parts List page for ordering information IMPORTANT Do not use any AC adaptor other than the EcoPure P N 7302835 with this Automatic Sediment Filter To install the optional AC adaptor 1 Remove the top...

Page 10: ...in will start and stop several times 4 Once the sediment flush has been completed the 2 digit display will change to show the number of days until the next automatic flush or if the automatic flush fe...

Page 11: ...increases the number of days by 1 When the number passes 30 it returns to zero indicated by and counts up from 1 again 3 Setting the number of days to zero turns off the automatic flush feature 4 When...

Page 12: ...e water you saved in Step 1 wash the filter screen assembly If necessary gently scrub the filter mesh with a soft brush to remove material from the pores 7 The drain straw may have come out of the ASF...

Page 13: ...off the water supply as directed in Step 2 run a bucketful or sinkful of water to use for cleaning 2 Shut off the main house water supply valve upstream from the Automatic Sediment Filter 3 Open a col...

Page 14: ...Head Assembly 17 7300312 O Ring Sump 18 7298395 Sump 19 7300304 Drain Straw Key No Part No Description 20 7298808 Filter Screen Assembly 60 Micron includes Key No 21 7298816 Filter Screen Assembly 100...