MATERIALS & TOOLS NEEDED

=

2 sweat adaptors, 1” NPT x sweat end to fit your

main water pipe

=

Lead-free solder and flux

=

Soldering torch

=

Teflon tape

=

Sandpaper or emery cloth

=

Wrench, either open end (to fit sweat adaptor) or

adjustable jaw

INSTALL FILTER ON PIPE

CAUTION:

Heat created when soldering can damage

the water filter’s plastic parts.  Be sure to use the fol-

lowing procedure to protect the water filter.

1

IMPORTANT:

Turn off the water supply to the main

pipe.  Open a high and low faucet in the water sys-

tem to drain the pipe.

2

. On the main water pipe, where you will install the fil-

ter, use a tubing cutter to remove a section of pipe

about 12" long.  Use sandpaper or emery cloth to

thoroughly clean and remove all burrs and rough

edges, from both pipe ends.

NOTE:

When soldering, use lead-free solder and flux

only.  Be sure pipe and fittings are properly

cleaned.

3

. Solder a sweat adaptor onto one of the pipe ends

(See Figure 14).

4

.  Place, but do not solder, a straight connector onto

the other pipe end (See Figure 14).

5

. After it cools, apply at least 4 wraps of Teflon tape to

the threads on the sweat adaptor fitting (See Figure

15).

NOTE:

If your installation will use the mounting brack-

et, position it correctly around the ASF 

before

installing inlet and outlet fittings.  The bracket

can not be put on after the inlet and outlet fit-

tings are installed.

6

. With the

IN

side of the water filter 

toward incoming

water

, carefully, turn the filter head onto the sweat

adaptor fitting (See Figure 15).  Do not cross-thread,

or overtighten and crack the filter head.  If neces-

sary to provide clearance to rotate the filter head,

temporarily remove the sump / screen assembly.

continued on next page

FIG. 14

Straight

Connector

Sweat

Adaptor

8

Installation - Type A (continued)

FIG. 12

WATER FLOW

IN

OUT

Nut

Nut

Fitting

Brass

Ferrule

8

. With the

IN

side of the water filter 

toward incoming

water

, spread the pipes apart and fit both pipe ends

into the compression fittings.  Move a ferrule and

nut up to the fitting (See Figure 12).  Then, turn on

and tighten the nut.  Hold the fitting with one wrench

while tightening the nut with the other.  Repeat on

the other side, again not overtightening.

NOTE

: Read the “Grounding Information” on Page 6,

and comply with the instructions if required to

maintain continuity.

9

. Do not turn the water supply back on yet.  

Go to

“Complete the Installation” on Page 10 and fol-

low the instructions to install the drain hose.

Installation - Type B

INSTALLATION USING SOLDERED COPPER FITTINGS

FIG. 13

WATER

IN

WATER

OUT

IN

OUT

Adaptor, 1” NPT

Sweat (Apply at

least 4 wraps of

Teflon Tape)

Optional

Shutoff

Valve (2)

1” Copper

Pipe, as

required

See Note in Figure 9

Summary of Contents for EP-ASF1

Page 1: ...l our toll free number 1 800 693 1138 Monday Friday 7 AM 6 PM CST or visit www ecopurewaterproducts com When you call please be prepared to provide the model date code and serial number of your produc...

Page 2: ...stallation Follow all steps exactly and in order to correctly install The Automatic Sediment Filter must only be installed vertically with the head up and the sump down It will not operate properly if...

Page 3: ...n and check against the packing list below Note any items lost or damaged in shipment If problems exist call our toll free number 1 800 693 1138 Monday Friday 7 AM 6 PM CST Packing List Mounting Brack...

Page 4: ...upstream from the water softener if any the water heater and all inside faucets See diagram below FIG 3 Water Softener Water Heater Hot Water to House Planning the Installation The unit has an electro...

Page 5: ...lter is installed on the plumbing 1 Remove the top cover from the ASF by sliding it upward 2 With a phillips screwdriver remove the 2 screws holding the faceplate assembly to the filter head See Figur...

Page 6: ...The Commonwealth of Massachusetts plumbing code 248 CMR shall be adhered to A licensed plumber shall be used for this installation AIR GAP REQUIREMENTS A drain is needed for sediment flush discharge w...

Page 7: ...ion at right so you do not forget 4 IMPORTANT Turn off the water supply to the main pipe Open a high and low faucet in the water sys tem to drain the pipe 5 On the main water pipe where you will insta...

Page 8: ...efore installing inlet and outlet fittings The bracket can not be put on after the inlet and outlet fit tings are installed 6 With the IN side of the water filter toward incoming water carefully turn...

Page 9: ...se Installation Type B continued Installation Type C INSTALLATION USING THREADED PIPE FITTINGS MATERIALS TOOLS NEEDED Pipe threading tool Pipe wrenches Pipe joint compound Union fittings Pipe Nipples...

Page 10: ...N 7302835 is available to supply 9V DC power to the electronic control instead of using a 9V battery This adaptor has 5 feet of wire One end plugs into a household 120V AC 60 Hz out let and the other...

Page 11: ...ow moving dashes See Figure 20 release the CLEAN NOW button 2 Check drain hose to ensure a secure connection 3 The sediment flush sequence takes about 30 sec onds to complete The flow of water to the...

Page 12: ...ated by and counts up from 1 again 3 Setting the number of days to zero turns off the automatic flush feature 4 When the desired number of days shows in the dis play wait 10 seconds press no more butt...

Page 13: ...ou saved in Step 1 wash the filter screen assembly If necessary gently scrub the filter mesh with a soft brush to remove material from the pores 7 The drain straw may have come out of the ASF head whe...

Page 14: ...t the sole noid seat requires cleaning use the following procedure 1 Before shutting off the water supply as directed in Step 2 run a bucketful or sinkful of water to use for cleaning 2 Shut off the m...

Page 15: ...further that the Automatic Sediment Filter is not damaged as the result of any unusu al force of nature such as but not limited to flood hurricane tornado or earthquake Warrantor is excused if failure...

Page 16: ...Sump 18 7298395 Sump 19 7300304 Drain Straw 20 7298808 Filter Screen Assembly 60 Micron includes Key No 21 7298816 Filter Screen Assembly 100 Micron includes Key No 21 7298824 Filter Screen Assembly 1...

Reviews: