background image

12

LED blinking

red

every 8

sec. indicates

battery is low

“E E” in the

display indi-

cates battery

is low

3

. Take a new 9-volt battery and snap the battery con-

nector onto both terminals.

4

. Place the connected battery into the clip provided

for it directly above the IN port (See Figure 18 on

Page 10).

5

. Slide the top cover back onto the ASF and push it

down to snap into place.

No reprogramming of the controller is necessary after

battery replacement or a power outage.

Electronic Controller (continued)

FIG. 23

The ASF controller is shipped with a default value of 7

days between automatic sediment flushes.  To change

the number of days (between 1 and 30) or to turn this

feature off:

1

. Press the PROGRAM button and hold it for at least

2 seconds.  When the LED turns on steadily with an

amber color, quickly release the PROGRAM button.

2

. While the amber LED is on (it turns off after 10 sec-

onds of button inactivity), repeatedly press the PRO-

GRAM button until the desired number of days

shows in the display.  Each press increases the

number of days by 1.  When the number passes 30,

it returns to zero, indicated by “- -”, and counts up

from 1 again.

3

. Setting the number of days to “- -” (zero) turns off

the automatic flush feature.

4

. When the desired number of days shows in the dis-

play, wait 10 seconds (press no more buttons) for

the amber LED to go off.  The new number of days

is programmed.  This new setting will remain after

battery change or power loss.

TIME OF DAY WHEN FLUSH OCCURS

The time of day when the automatic sediment flush will

occur is the same time of day as when the most recent

of the following was done:

=

The filter was powered up (battery installed or

replaced, optional AC adaptor plugged in)

=

The number of days was set

=

A manual flush was initiated

If a different time of day is desired for automatic flush,

simply initiate a manual flush (as described on the pre-

vious page) at the desired time of day.

LOW BATTERY INDICATION

If the LED is blinking red every 8 seconds (and the 2-

digit display shows “E E“), then the battery needs to be

replaced.

BATTERY REPLACEMENT

1

. Remove the top cover from the ASF by sliding it

upward (See Figure 18 on Page 10).

2

. Locate the old battery and unsnap it from the bat-

tery connector.  Dispose of (recycle) old battery

properly.

FIG. 22

SETTING THE NUMBER OF DAYS BE TWEEN

AUTOMATIC SEDIMENT FLUSHES

Two dashes

(not moving)

in the display

indicate auto-

matic flush is

turned off

Summary of Contents for EP-ASF1

Page 1: ...l our toll free number 1 800 693 1138 Monday Friday 7 AM 6 PM CST or visit www ecopurewaterproducts com When you call please be prepared to provide the model date code and serial number of your produc...

Page 2: ...stallation Follow all steps exactly and in order to correctly install The Automatic Sediment Filter must only be installed vertically with the head up and the sump down It will not operate properly if...

Page 3: ...n and check against the packing list below Note any items lost or damaged in shipment If problems exist call our toll free number 1 800 693 1138 Monday Friday 7 AM 6 PM CST Packing List Mounting Brack...

Page 4: ...upstream from the water softener if any the water heater and all inside faucets See diagram below FIG 3 Water Softener Water Heater Hot Water to House Planning the Installation The unit has an electro...

Page 5: ...lter is installed on the plumbing 1 Remove the top cover from the ASF by sliding it upward 2 With a phillips screwdriver remove the 2 screws holding the faceplate assembly to the filter head See Figur...

Page 6: ...The Commonwealth of Massachusetts plumbing code 248 CMR shall be adhered to A licensed plumber shall be used for this installation AIR GAP REQUIREMENTS A drain is needed for sediment flush discharge w...

Page 7: ...ion at right so you do not forget 4 IMPORTANT Turn off the water supply to the main pipe Open a high and low faucet in the water sys tem to drain the pipe 5 On the main water pipe where you will insta...

Page 8: ...efore installing inlet and outlet fittings The bracket can not be put on after the inlet and outlet fit tings are installed 6 With the IN side of the water filter toward incoming water carefully turn...

Page 9: ...se Installation Type B continued Installation Type C INSTALLATION USING THREADED PIPE FITTINGS MATERIALS TOOLS NEEDED Pipe threading tool Pipe wrenches Pipe joint compound Union fittings Pipe Nipples...

Page 10: ...N 7302835 is available to supply 9V DC power to the electronic control instead of using a 9V battery This adaptor has 5 feet of wire One end plugs into a household 120V AC 60 Hz out let and the other...

Page 11: ...ow moving dashes See Figure 20 release the CLEAN NOW button 2 Check drain hose to ensure a secure connection 3 The sediment flush sequence takes about 30 sec onds to complete The flow of water to the...

Page 12: ...ated by and counts up from 1 again 3 Setting the number of days to zero turns off the automatic flush feature 4 When the desired number of days shows in the dis play wait 10 seconds press no more butt...

Page 13: ...ou saved in Step 1 wash the filter screen assembly If necessary gently scrub the filter mesh with a soft brush to remove material from the pores 7 The drain straw may have come out of the ASF head whe...

Page 14: ...t the sole noid seat requires cleaning use the following procedure 1 Before shutting off the water supply as directed in Step 2 run a bucketful or sinkful of water to use for cleaning 2 Shut off the m...

Page 15: ...further that the Automatic Sediment Filter is not damaged as the result of any unusu al force of nature such as but not limited to flood hurricane tornado or earthquake Warrantor is excused if failure...

Page 16: ...Sump 18 7298395 Sump 19 7300304 Drain Straw 20 7298808 Filter Screen Assembly 60 Micron includes Key No 21 7298816 Filter Screen Assembly 100 Micron includes Key No 21 7298824 Filter Screen Assembly 1...

Reviews: