background image

16

Key

No.

Part No.

Description

1

7298442

Top Cover

2

7295177

Electronic Control Board (PWA)

3

7298434

Faceplate (order decal below)

4

7300354

Decal, Faceplate, EcoPure

5

7300346

Screw, 6-19 x 1/2” (2 req.)

6

7301596

Solenoid

7

7301758

O-Ring, Solenoid

8

7300338

Screw, 10-16 x 1-1/4” (6 req.)

9

7298426

Valve Cover

10

7301520

Spring

11

7301685

Retainer, Spring

12

7301512

Diaphragm

13

7298418

Valve Body

14

7300320

O-Ring, Valve (2 req.)

15

7272658

Check Valve

16

7298387

Head Assembly

17

7300312

O-Ring, Sump

18

7298395

Sump

19

7300304

Drain Straw

20

7298808

Filter Screen Assembly,

60 Micron (includes Key No. 21)

7298816

Filter Screen Assembly, 100

Micron (includes Key No. 21) 

Ù

7298824

Filter Screen Assembly, 150

Micron (includes Key No. 21) 

Ù

21

7011086

O-Ring, Filter

22

7139999

Drain Hose, 20 ft.

23

0900431

Clamp, Drain Hose

24

7301368

Bracket, Mounting

25

9006053

Screw, 10-16 AB (2 req.)

26

7302835

AC Power Adaptor 

Ù

27

Battery, 9 Volt, Standard

¢

7301570

Owner’s Manual

¢

Not illustrated.

Ù

Optional - not included with Automatic Sediment Filter.

Repair Parts

To order repair parts call toll free

1-800-693-1138

,

Monday - Friday, 7 am - 6 pm CST.

1

2

3

5

4

6

7

8

9

11

10

12

13

14

27

16

17

19

20

18

22

23

24

25

26

21

15

Summary of Contents for EP-ASF1

Page 1: ...l our toll free number 1 800 693 1138 Monday Friday 7 AM 6 PM CST or visit www ecopurewaterproducts com When you call please be prepared to provide the model date code and serial number of your produc...

Page 2: ...stallation Follow all steps exactly and in order to correctly install The Automatic Sediment Filter must only be installed vertically with the head up and the sump down It will not operate properly if...

Page 3: ...n and check against the packing list below Note any items lost or damaged in shipment If problems exist call our toll free number 1 800 693 1138 Monday Friday 7 AM 6 PM CST Packing List Mounting Brack...

Page 4: ...upstream from the water softener if any the water heater and all inside faucets See diagram below FIG 3 Water Softener Water Heater Hot Water to House Planning the Installation The unit has an electro...

Page 5: ...lter is installed on the plumbing 1 Remove the top cover from the ASF by sliding it upward 2 With a phillips screwdriver remove the 2 screws holding the faceplate assembly to the filter head See Figur...

Page 6: ...The Commonwealth of Massachusetts plumbing code 248 CMR shall be adhered to A licensed plumber shall be used for this installation AIR GAP REQUIREMENTS A drain is needed for sediment flush discharge w...

Page 7: ...ion at right so you do not forget 4 IMPORTANT Turn off the water supply to the main pipe Open a high and low faucet in the water sys tem to drain the pipe 5 On the main water pipe where you will insta...

Page 8: ...efore installing inlet and outlet fittings The bracket can not be put on after the inlet and outlet fit tings are installed 6 With the IN side of the water filter toward incoming water carefully turn...

Page 9: ...se Installation Type B continued Installation Type C INSTALLATION USING THREADED PIPE FITTINGS MATERIALS TOOLS NEEDED Pipe threading tool Pipe wrenches Pipe joint compound Union fittings Pipe Nipples...

Page 10: ...N 7302835 is available to supply 9V DC power to the electronic control instead of using a 9V battery This adaptor has 5 feet of wire One end plugs into a household 120V AC 60 Hz out let and the other...

Page 11: ...ow moving dashes See Figure 20 release the CLEAN NOW button 2 Check drain hose to ensure a secure connection 3 The sediment flush sequence takes about 30 sec onds to complete The flow of water to the...

Page 12: ...ated by and counts up from 1 again 3 Setting the number of days to zero turns off the automatic flush feature 4 When the desired number of days shows in the dis play wait 10 seconds press no more butt...

Page 13: ...ou saved in Step 1 wash the filter screen assembly If necessary gently scrub the filter mesh with a soft brush to remove material from the pores 7 The drain straw may have come out of the ASF head whe...

Page 14: ...t the sole noid seat requires cleaning use the following procedure 1 Before shutting off the water supply as directed in Step 2 run a bucketful or sinkful of water to use for cleaning 2 Shut off the m...

Page 15: ...further that the Automatic Sediment Filter is not damaged as the result of any unusu al force of nature such as but not limited to flood hurricane tornado or earthquake Warrantor is excused if failure...

Page 16: ...Sump 18 7298395 Sump 19 7300304 Drain Straw 20 7298808 Filter Screen Assembly 60 Micron includes Key No 21 7298816 Filter Screen Assembly 100 Micron includes Key No 21 7298824 Filter Screen Assembly 1...

Reviews: