background image

10

INSTALL THE DRAIN HOSE

Do the following before turning the water supply back

on:

1

. Measure, cut to needed length and connect the 3/8”

drain line (provided) to the Automatic Sediment

Filter’s valve drain fitting (See Figure 8 on Page 6).

Use a hose clamp to hold hose in place.

2

. Run the drain hose or copper tubing to the floor

drain.  Secure drain hose.  This will prevent the

drain line from “whipping'' during sediment flush

cycles.  See “Air Gap Requirements" section.

CHECK FOR LEAKS

1

. With the installation steps completed, fully open the

home’s main water supply valve.

2

. Check for leaks at all the plumbing connections you

made.

3

. Make sure the electronics are completely dry before

powering the unit up (as described in the next sec-

tion).

INSTALL BATTERY

1

. Take the included 9V battery out of its plastic wrap.

2

. Remove the top cover from the ASF by sliding it

upward (See Figure 18).

3

. Snap the battery connector onto both terminals of

the 9V battery.

4

. Place the connected battery into the clip provided

for it directly above the IN port (See Figure 18).

5

. Slide the top cover back onto the ASF and push it

down to snap into place.

OPTIONAL AC ADAPTOR (not included)

An optional AC adaptor (P/N 7302835) is available to

supply 9V DC power to the electronic control instead

of using a 9V battery.  This adaptor has 5 feet of wire.

One end plugs into a household 120V AC, 60 Hz. out-

let and the other end plugs into the back of the elec-

tronic control board, as shown in Figure 19.  See the

Repair Parts List page for ordering information.

IMPORTANT:

Do not use any AC adaptor other than

the EcoPure P/N 7302835 with this

Automatic Sediment Filter.

To install the optional AC adaptor:

1

. Remove the top cover from the ASF by sliding it

upward (See Figure 19).

2

. Remove any previously installed 9V battery from the

ASF (disconnect it from the battery connector and

lift it out of the clip above the IN port).

Complete the Installation 

(all Installation types)

FIG. 18

Clip

9V Battery

Top Cover

Battery Connector

3

. Locate the small round plug on one end of the AC

adaptor cable and insert this into the connector on

back of the electronic control board (See Figure 19).

4

. Plug the other end of the AC adaptor into a 120V,

60 Hz household electric socket.

5

. Before replacing the cover on the ASF, feed the wire

through the small slot above the IN port of the ASF

(See Figure 19).

6

. Slide the top cover back onto the ASF, making sure

not to pinch any wires, and push it down to snap

into place.

FIG. 19

Optional

AC Adaptor

Top Cover

Feed

Wire

through

Slot

Plug into

Connector on

Electronic

Control Board

Summary of Contents for EP-ASF1

Page 1: ...l our toll free number 1 800 693 1138 Monday Friday 7 AM 6 PM CST or visit www ecopurewaterproducts com When you call please be prepared to provide the model date code and serial number of your produc...

Page 2: ...stallation Follow all steps exactly and in order to correctly install The Automatic Sediment Filter must only be installed vertically with the head up and the sump down It will not operate properly if...

Page 3: ...n and check against the packing list below Note any items lost or damaged in shipment If problems exist call our toll free number 1 800 693 1138 Monday Friday 7 AM 6 PM CST Packing List Mounting Brack...

Page 4: ...upstream from the water softener if any the water heater and all inside faucets See diagram below FIG 3 Water Softener Water Heater Hot Water to House Planning the Installation The unit has an electro...

Page 5: ...lter is installed on the plumbing 1 Remove the top cover from the ASF by sliding it upward 2 With a phillips screwdriver remove the 2 screws holding the faceplate assembly to the filter head See Figur...

Page 6: ...The Commonwealth of Massachusetts plumbing code 248 CMR shall be adhered to A licensed plumber shall be used for this installation AIR GAP REQUIREMENTS A drain is needed for sediment flush discharge w...

Page 7: ...ion at right so you do not forget 4 IMPORTANT Turn off the water supply to the main pipe Open a high and low faucet in the water sys tem to drain the pipe 5 On the main water pipe where you will insta...

Page 8: ...efore installing inlet and outlet fittings The bracket can not be put on after the inlet and outlet fit tings are installed 6 With the IN side of the water filter toward incoming water carefully turn...

Page 9: ...se Installation Type B continued Installation Type C INSTALLATION USING THREADED PIPE FITTINGS MATERIALS TOOLS NEEDED Pipe threading tool Pipe wrenches Pipe joint compound Union fittings Pipe Nipples...

Page 10: ...N 7302835 is available to supply 9V DC power to the electronic control instead of using a 9V battery This adaptor has 5 feet of wire One end plugs into a household 120V AC 60 Hz out let and the other...

Page 11: ...ow moving dashes See Figure 20 release the CLEAN NOW button 2 Check drain hose to ensure a secure connection 3 The sediment flush sequence takes about 30 sec onds to complete The flow of water to the...

Page 12: ...ated by and counts up from 1 again 3 Setting the number of days to zero turns off the automatic flush feature 4 When the desired number of days shows in the dis play wait 10 seconds press no more butt...

Page 13: ...ou saved in Step 1 wash the filter screen assembly If necessary gently scrub the filter mesh with a soft brush to remove material from the pores 7 The drain straw may have come out of the ASF head whe...