These HRV's are designed for installation on a hard surface of an external wall, in a loft, in
a roof space, under the floor, in a basement, or on the roof. For maximum effectiveness,
the HRV should be installed halfway between the Return Air Grille and the Supply Air Grille.
3.2 PHYSICAL SPECS
Dimensions of models;
Length collar to collar:
760 mm (AV/EV)
815 mm (FV)
Height:
510 mm
Width:
240 mm
Weight excl. wall brackets: 12.5 kg (EV)
12 kg (AV/FV)
Note
: Any ducting and vents for installation are not supplied with the HRV's. Insulated
Flexi/solid ducts are recommended for the Return Air from indoor to the unit.
Inlet outlet collar sizes for ducting
AussiVent and EcoVent models AV80, AV120, EV80, and EV120 are fitted with
6 inch
collars for fresh air intake, fresh air supply, indoor air intake, and indoor air exhaust.
Fresh Vent models FV80 and FV120 are fitted all with
3 inch
outlets suitable for cool room
applications.
All the above models are supplied in weather resistant UV stabilised ABS plastic, rugged
enough for long endurance.
Electricians please follow the following three steps to install the HRV on the wall using the
steel brackets and bolts shown below through three illustrations.
Wall brackets- Illustration 5
Fasten the joiner in the middle to the two wall brackets as shown above.