Eco Pacific AussiVent Installation, Operation And Service Instructions Download Page 3

P a g e

 | 

 

Version10- March 2017 

Eco Pacific Pty Ltd 

Standard heating and cooling appliances fitted in houses often recycle the same bad air 
that residents inhale and exhale, including the unhealthy emissions coming from kitchens 
and toilets, compelling the residents to seriously compromise their health.  Constant 
exposure to bad air for a long time can lead to lung disorders, and can cause itching of the 
throat and eyes, laziness, and poor concentration of mind.  The HRV addresses these 
indoor air quality issues.

 

The Fresh Air Ventilator with heat recovery is highly recommended for use in Cool 
Rooms, Residential Apartments, Health Clinics, Hospitals, Hotels, Schools, Aged 
Care Facilities, and Offices, just to name a few.

 

All enquiries related to this innovation should be addressed to Eco Pacific Pty Ltd at 
tel61 3 9706 6228 or through email at 

[email protected]

 

1.2  HEAT EXCHANGER 

The Eco Pacific Heat Exchanger has been tested to ASHRAE 84 standard for Air -To - Air 
Heat/ Energy Exchange, by Australia’s NATA accredited test lab, VIPAC Engineers and 
Scientists, for thermal performance and pressure drop (Report ref.30S-15-0158-TRP-
392476-1-2016). 

 

1.3  MODELS AND THEIR DISTINCTIONS 

There are three models which all utilise a common thermal transfer process.  The fresh air 
ventilator is fitted with a Heat Exchanger in the centre of its cabinet, and is connected with 
an external filter box to introduce atmospheric air through a duct sized to the installation.  
The Filter Box remains accessible to the user for filter service, and filters outdoor polluted 
air and introduces it in the living space after passing through the Heat Exchanger which 
transfers heat or cool from the higher temperature stream to the lower temperature stream 
coming from opposite direction.  The HRV removes the contaminated air of the room by 
exhausting this air through the Heat Exchanger that recovers the heat or cool of the 
contaminated indoor air, and transfers it to the incoming fresh filtered air.  The HRV is able 
to deliver the fresh filtered air at near room temperature in all seasons irrespective of the 
outdoor air temperature. 

The 3 models of HRV are; 

1. 

AussiVent 

designed to provide fresh filtered air with heat recovery to homes. 

Two sizes are available, namely AV80 and AV120 that are both suitable from 2 bed 
room to 4 bed room apartments and houses accommodating up to 10 people. 

 

 

Summary of Contents for AussiVent

Page 1: ...ions Fresh Filtered Air Ventilators with Efficient Heat Cool Recovery from Indoor Air Models AussiVent EcoVent FreshVent Please read these instructions prior to installation Manufactured by Eco Pacifi...

Page 2: ...e to temperature difference With an energy recovery effectiveness of up to 85 the HRV delivers fresh filtered air at near room temperatures in all seasons irrespective of outdoor temperatures The HRV...

Page 3: ...mance and pressure drop Report ref 30S 15 0158 TRP 392476 1 2016 1 3 MODELS AND THEIR DISTINCTIONS There are three models which all utilise a common thermal transfer process The fresh air ventilator i...

Page 4: ...le namely FV80 and FV120 Illustration 1 Physical appearance of the three models with their dedicated controls 1 4 FILTER BOX The Filter Box is the same for all the models The filter cassette can be cu...

Page 5: ...FLOWS AV80 EV80 and FV80 provide air flows of 80 l s at 100 Pa external static pressure ESP AV120 EV120 and FV120 provide air flows of 120 l s at 100 Pa ESP Note the Filter Sensor is fitted to the sta...

Page 6: ...y docket with photo evidence attached and be sent to the local agent dealer The damage should be claimed within three days from inspection The manufacturer supplying the HRV relies on the dealer contr...

Page 7: ...lated Flexi solid ducts are recommended for the Return Air from indoor to the unit Inlet outlet collar sizes for ducting AussiVent and EcoVent models AV80 AV120 EV80 and EV120 are fitted with 6 inch c...

Page 8: ...Eco Pacific Pty Ltd Use the M5 bolts 2 each side on the wall brackets Put the HRV on the bracket slide it through and fasten it on to the brackets using two M5 bolts each side threading from the botto...

Page 9: ...and insects The indoor air inlet should also be fitted with a wire mesh filter inside the grille to protect the heat exchanger from dirt scaling and insects and should be cleaned monthly 3 4 SERVICE...

Page 10: ...aggravates the ripening process occasionally culminating with rotting of the Produce The FreshVent HRV can remove the ethylene and bring fresh filtered air into the cold room to slow down the ripenin...

Page 11: ...ir The drain pipe should have gravity fall of at least one inch for every 3 meter length of the drain pipe to the nearest down pipe to the ground Comply with local authorities in regards to drain disc...

Page 12: ...P a g e 12 Version10 March 2017 Eco Pacific Pty Ltd Illustration 8 Wiring diagram for AussiVent and FreshVent models with AV fans...

Page 13: ...air tight 9 Check the wall controller is mounted firmly on the wall with clear passage to the power cord and tele connector without interfering with its surrounding Make sure the wall controller s vic...

Page 14: ...P a g e 14 Version10 March 2017 Eco Pacific Pty Ltd Illustration 9 wiring diagram for EcoVent with AV fans...

Page 15: ...is free to allow air flow Check outdoor air inlet in the filter Clean the filter Check fan motor operation 3 HRV is running noisy Check the fan wheel is not touching the cabinet if yes call the servic...

Page 16: ...ower from the power outlet To access a motor remove the two base screws and the two lid screws of that motor end of casing Lift the side panels slightly above the base and pull out this end panel gent...

Page 17: ...on10 March 2017 Eco Pacific Pty Ltd Illustration 12 Filter side power and wall controller connections for motor and the H X Illustration 13 Base screws 2 at each end to separate the side panels to ser...

Page 18: ...ed by a faulty installation or maintenance not in accordance with the recommended ECO PACIFIC maintenance schedule Eco Pacific Pty Ltd reserves the right to void the Warranty where the agreed payment...

Reviews: