E93.1001EN.C Manual CD
+
31
E
XAMPLE
D:
C
ONCENTRIC
C33
(
ROOF
-
MOUNTED
)
Calculation example with given lengths: checking resistance
Water heater type:
CD
+
80
C
oncent
ri
c
Diameter: 80/125 mm.
Number
Pa
Pa total
Straight tube m
total
11
12
132
Bend
90°
3
13
39
Bend
45°
2
7
14
Concentric terminal
roof
1
61
61
Total resistance flue gas outlet and air supply
(concentric):
246
The total resistance is less than 200 Pa. This flue gas / air supply system is
functional.
Part number concentric roof terminal: E04.018.015 – Inox
E04.018.018 - PP
E
XAMPLE
E:
C
ONCENTRIC SYSTEM
W
ALL OUTLET
C13
(
WALL
-
MOUNTED
)
Calculation example with given lengths: checking resistance
The total resistance is less than 200 Pa. This flue gas / air supply system
is functional.
Part number concentric wall terminal: E04.018.019 - Inox
Water heater type:
CD
+
80
C
oncent
ri
c
Diameter: 80/125 mm
Number
Pa
Pa total
Straight tube m
total
9
12
108
Bend
90°
1
13
13
Concentric terminal
wall
1
22
22
Total resistance flue gas outlet and air supply
(concentric):
143
60
60
80
80