ENGLISH
Instruction manual CASA IV
27
9 DISPOSAL
WEEE Reg.-Nr.: DE69510123
This product complies with EU Directive 2002/96/EC and is registered according to WEEE (Waste Electrical and
Electronic Equipment).
10 CE CONFORMITY
Conformity
The product complies with the following EU Directives:
Machine:
98/37/EC
Low Voltage:
73/23/EEC, 93/68/EEC
EMC:
89/336/EEC, 93/68/EEC, 92/31/EEC
PED:
97/23/EC
EN-Directives:
EN 292-1, EN 292-2, EN 60335-1, EN 60335-2-15 or EN 60335-2-75, EN 55014, EN 61000-3,
EN 61000-4, ENV 50141, EN 55104
11 TROUBLESHOOTING
Problem
Possible cause
Troubleshooting
The grind is not fine enough.
Use a finer grind.
Tamp the ground coffee more firmly.
Reduce the brewing pressure.
The coffee is too old.
Use fresh coffee.
There is too much chlorine in the
water.
Use a chlorine filter.
The amount of ground coffee is not
enough.
Use the right coffee amount:
Approx. 7 g of coffee for each cup.
Little or no crema on top of the
coffee
The shower screen is dirty.
Clean the brew group.
The grind is too fine.
Increase the grind setting.
Tamp the ground coffee only
slightly.
Increase the brewing pressure.
There is too much ground coffee.
Use approx. 7 g of coffee for every
cup.
Sparse coffee dispensing, only drop
by drop
The water tank is empty.
Refill the water tank.
The grind is not fine enough.
Reduce the grind setting.
The coffee is old.
Use fresh coffee.
The amount of ground coffee is not
enough.
Use approx. 7 g of coffee for each
cup, about ¼ ounce.
Weak “body”
The shower screen is dirty.
Clean the shower screen.
The coffee beans are improper.
Use another coffee bean.
Foam instead of crema
The setting of the coffee grinder is
not suited for the coffee beans in
use.
Adjust the coffee grinder (when
changing the coffee beans, changing
the grind may also be necessary).
Water is low in the tank.
Refill the water tank with water.
The boiler is empty after steam
dispension.
Refill the boiler after steam
dispension.
Machine is switched on, but no
water is released from the brew
group.
The water tank is not fixed properly.
Fix the water tank properly.
The steam switch is switched on.
Switch off the steam switch.
Brew group releases steam/
temperature for coffee preparation is
too high
The water tank is empty.
Refill the water tank and release
water from of the brew group.
The boiler is empty.
Refill the boiler.
The steam dispension does not
work.
The nozzle is blocked.
Clean the nozzle.
The filter is blocked.
Clean the filter.
The coffee dispension is irregular.
The grind is not correct.
Change the grind.