background image

9

8

WARNING! This system incorporates strong permanent magnetic materials. 

Please pay attention to the safety notes in order to avoid personal injury or 

material damage:

• 

Operators fitted with a heart pace-maker shall not come within 1m of the equipment

• 

Oppositional poles of magnets attract each other with high clamping forces

• 

Do not use steel/iron tools or other ferrous parts in the flux field of the system

• 

Data carriers, credit cards, computer drives etc. can be erased by the influence of the 
magnetic field 

• 

Keep electronic and sensitive mechanical units (for example, watches) away from the 
magnet

• 

Please contact our service department before welding or drilling works on the unit 

4.5  Notes on residual risks

Vent any trapped pressure from the equipment prior to working on the unit.

4.6  Consequences with arbitrary change

With arbitrary change or repairs all warranties and assertions delivered by the manufacturer 
become void. 

Only genuine o.e.m. parts are to be used in any repair to maintain the manufacturer’s 
warranty.

4.7  Prohibited operation

• 

The unit must not be subjected to any high external loads or induced vibrations

5  Installation and use

5.1  Mechanical installation 

For optimum performance the unit is to be installed as follows:

Before installation ensure that all supplies are isolated.

Micromag HP/80NPT is to be installed vertically with the bowl pointing 

upwards

, this allows 

fluid to drain out of the bowl and into the line prior to cleaning.

Micromag can be installed anywhere in the fluid flow line, pre- or post-pump to suit the 
application, using the threaded ports supplied.

If the Micromag is to be installed using flexible hoses, please ensure the unit is suitably 
supported using the bracket holes supplied on the lid.

The lid is engraved near its ports with ‘inlet’ and ‘outlet’ please ensure these directions are 
followed for correct performance. 

For ease of installation remove the lid from the bowl.

If the system is subject to pressure surges install a pressure regulator set at 1160 psi (80 bar) 
prior to the Micromag HP/80NPT.

• 

Seal mating piping joints effectively to reduce pressure/product loss

• 

Erect signage in the close proximity warning of hazards presented by permanent mag-
nets, i.e. pace-makers and the dangers of opening the magnet housing whilst product is 
flowing

• 

Install in location with adequate free space to withdraw magnet cartridge from vessel for 
cleaning

• 

Consider manual handling regulations when deciding installation location

5.2 Connections

No external power sources required for this product

5.3  Setting of the operating parameter

No customer adjustment available to this unit

Summary of Contents for Micromag HP/80NPT

Page 1: ...de to ensure the accuracy of the information in this publication please note that specifications may change without notice Eclipse Tools North America Inc 442 Millen Road Unit 9 Stoney Creek ON L8E 6H...

Page 2: ...APPROVED PRODUCT 1 2 Used symbols Important notes Danger notes Safety notes Contents 1 Introduction 1 1 Range of application 3 1 2 Used symbols 3 1 3 Overview 4 2 Technical data 2 1 Performance data 5...

Page 3: ...e MM10 HP 80NPT 26 gallons minute MM20 HP 80NPT 40 gallons minute Vessel Stainless Steel Magnetic characteristics max operating temperature NdFeB HT material 284 F 140 C Port size and contamination ca...

Page 4: ...s above the specific operating temperature 2 NO oscillating vibrations 3 NO impacts 4 NO strong external magnetic flux fields 5 Pay attention to the cleaning and maintenance of the system 4 2 General...

Page 5: ...nit is to be installed as follows Before installation ensure that all supplies are isolated Micromag HP 80NPT is to be installed vertically with the bowl pointing upwards this allows fluid to drain ou...